Download Netra 440 Server Diagnostics and Troubleshooting Guide

Transcript
9. To reboot the system, type:
ok reset-all
The system stores the OpenBoot configuration variable settings and boots
automatically when the auto-boot? variable is set to true.
Try replacing the FRU or FRUs indicated by OpenBoot Diagnostics error messages, if
any. For FRU replacement instructions, refer to the Netra 440 Server Service Manual.
Viewing Diagnostic Test Results After
the Fact
Summaries of the results from the most recent power-on self-test (POST) and
OpenBoot Diagnostics tests are saved across power cycles.
▼
To View Diagnostic Test Results
1. Log in to the system console and access the ok prompt.
2. View the desired category of test results.
■
To see a summary of the last execution of POST diagnostics, type:
ok show-post-results
■
To see a summary of the last execution of OpenBoot Diagnostics tests, type:
ok show-obdiag-results
You should see a system-dependent list of hardware components, along with an
indication of which components passed and which failed POST or OpenBoot
Diagnostics tests.
64