2.
Route low voltage wire from load control device to terminal
block.
Connect field wiring to “RP” and “P” positions.
Dry Contact Peak
Control Switch
The maximum coil size the factory supplied return air
plenum can accomodate through the front access is
25.5" (W) x 22" (D) x 29.93" (H). The inner dimensions
of the coil area are 26" (W) x 22" (D) x 30.96" (H).
8
Blower
Speed
P4
Water
R1
Y12 Y2 2 O 2
D2
R2
D1
P10
P5
P3
P2
Peak
Inputs
Aux.
Relay
RP P AP
P1
P8
Air
E J6
A
B
C
D
C3
Y2 J5
D5 D7 D3
R C
J1
J2
J3
J4
P11
O H/E
Y1
The 3120 Comfort Plus heating system can accommodate most heat pump or air conditioner indoor
coils up to a 3 1/2 ton capacity provided the heat
pump or air conditioner is sized in accordance to
supply air delivery rates of the Comfort Plus.
W
W/
AUX Y1 Y2 G
Outdoor
Outdoor
Risk of fire. Any one ducting system MUST
NOT contain more than one air handling
(blower) system.
Comfort Plus
LV Circuit Board
P6
P9
R
C
P7
D6
RLY1
D4
Fid 2
To Control Board
Blower
To Control Board
If utilizing a Steffes Time Clock Module or Power Line
Carrier control, refer to the instructions shipped with that
device for installation information.
LINE VOLTAGE ELECTRICAL CONNECTIONS
B L O W E R S /C O N T R O L S C IR C U IT
C H A R G E C IR C U IT # 1
WARNING
C H A R G E C IR C U IT # 2
HAZARDOUS VOLTAGE: Risk of electric shock. Can cause injury or
death. Do not energize the Comfort Plus heating system until installation is complete.
LINE 2
C ir c u it B r e a k e r s
Full Load Current
• To reduce electromagnetic fields associated with electrical
circuits and to avoid induced voltage on sensors and electronic
devices, the circuit phases MUST be alternated as shown.
Show n for 240VAC only. Circuit deration not included.
Model
• DO NOT install any wiring in the line voltage compartment of
the Comfort Plus heating system unless it is rated for line
voltage.
Control Crct Chrg Crct #1 Chrg Crct #2
3120 - 14.0kW
6.00
29.17
29.17
3120 - 17.0kW
6.00
36.46
36.46
3120 - 21.6kW
6.00
45.00
45.00
LOW VOLTAGE OUTDOOR SENSOR CONNECTIONS
R2
RLY1
Fid 2
Blower
Speed
P4
D2
P10
D1
P5
P3
P2
NC
P8
Comfort Plus
LV Circuit Board
R
P7
P6
D6
D4
Blower
To Control Board
NO
Aux.
Relay
COM
Peak
Inputs
RP P AP
P1
Air
C3
R1
Y12 Y22 O2
Water
D5 D7 D3
R C
E J6
A
B
C
D
P11
O H/E
Y2 J5
W/
AUX Y1 Y2 G
Outdoor
Outdoor
Outdoor Sensor
W
Direct Wired:
1. Mount outdoor sensor in a location where it can accurately
sense outdoor temperature.
2. Route low voltage wire from outdoor sensor to electrical
compartment:
•
Outdoor sensor wire MUST NOT be combined with other
control wiring in a multi-conductor cable.
•
Seal external wall openings.
•
Outdoor sensor lead can be extended to 250 ft.
•
Unshielded Class II (thermostat) wire can be used
provided it is segregated from any line voltage wiring.
3. Connect outdoor sensor wires to the two "OUTDOOR" positions of the low voltage terminal block.
If connecting to the Steffes power line carrier system, follow the installation instructions in the PLC
system’s Owner’s and Installer’s Guide.
J1
J2
J3
J4
The outdoor temperature sensor can be installed by wiring it
directly to the system or to the Steffes power line carrier (PLC)
system.
Y1
9
LINE 1
• To ensure proper operation and safety, all line voltage circuits
must be segregated from low voltage wiring.
LINE 1
Make proper field wiring connections, phasing circuits as shown.
Reference the Unit Identification label for circuit information.
LINE 2
2.
LINE 2
Route all line voltage wires through knockout(s) and into electrical panel.
LINE 1
1.
To Service (Breaker) Panel
WARNING
1.
LOW VOLTAGE PEAK CONTROL
CONNECTIONS
NO
When interfacing a heat pump with the Comfort Plus,
the A-coil MUST be placed in the return air plenum.
7
NC
AIR CONDITIONER/HEAT
PUMP INTERFACE
COM
6
To Control Board
P9
C