Download RUGGEDCOM RS416

Transcript
RUGGEDCOM RS416
Chapter 2
Installation Guide
Installing Device
3
5
3
5
1
2
4
4
Figure 12: Failsafe Alarm Relay Wiring
1. Screw-Type Terminal Block
Terminal
2. Pluggable Terminal Block
3. Normally Open Terminal
4. Common Terminal
5. Normally Closed
Section 2.4
Grounding the Device
The RS416 chassis ground terminal uses a #6-32 screw. It is recommended to terminate the ground connection
with a #6 ring lug and torque it to 1.7 N·m (15 lbf·in).
2
3
1
Figure 13: Chassis Ground Connection
1. Stainless Steel Stud
2. #6-32 Screw
3. #6 Ring Lug
Section 2.5
Connecting to the Device
The following describes the various methods for accessing the ROS console and Web interfaces on the device.
For more detailed instructions, refer to the ROS User Guide for the RS416.
Grounding the Device
15