button. To go back to the main menu (HEAT, COOL, CIRC, MANU), push on the MODE button. After two minutes
of inactivity on the keyboard, the display will shut itself off.
The Selections
KIP (Kick-in Point - start-up temperature of the furnace blower)
Using the arrows, increase or decrease the temperature at which the furnace distribution blower will start
functioning. You can adjust the temperature between 125oF (52oC) and 150oF (65oC). After two minutes of inactivity
on the keyboard, the display will shut itself off. The KIP must be programmed if the furnace is operated under the
HEAT or MANU modes.
TEMP (Temperature)
By pushing the arrows, you will see the current temperature inside the main hot air plenum of your furnace. After two
minutes of inactivity on the keyboard, the display will shut itself off. The TEMP selection has no impact on the
operation of the furnace. It is offered as a practical way for an installer or a technician to quickly obtain the
temperature inside the hot air plenum under the HEAT or MANU modes if a problem arises and the temperature
must be known in order to trouble shoot the furnace.
UNIT (measuring unit)
By pushing the arrows, you will select the measuring unit that you wish to use (Fahrenheit or Celsius). Thereafter,
temperatures will be displayed according to your selection. After two minutes of inactivity on the keyboard, the
display will shut itself off. The UNIT selections has no impact on the operation of the furnace. It is simply a
preference chosen by the technician or the user of the product..
FAN (blower speed)
Using the arrows, increase or decrease the blower speed. You can choose from six preselected speeds. This
selection is very important for the modes COOL, MANY, or CIRC. There is a choice of 6 different speeds. Under
the COOL mode, the speed selected is the speed at which the distribution blower will work when a cooling demand
will be sent by the thermostat. Under the MANU mode, it is the speed at which the distribution blower will work
when a heating demand will be sent by the thermostat and that the hot air plenum will have reached its kick-in
temperature (KIP). Under the CIRC mode, it is the speed at which the distribution blower will run to circulate the air
inside the house during summer. The CIRC mode will also be used by the technician to manually select speed #4 in
order to balance the system upon installation of the furnace.
Note: The FAN selection is not necessary under the HEAT mode because it is the PC board that automatically
chooses the speed at which the distribution blower runs in order to maintain the BEP inside the hot air plenum.
LIGHTING
1. Open the furnace door
Note: If there is already a bed of coals in the firebox, go to pre-heating.
2. Place one or two dry kindlings at the front of the furnace.
3. Place newspaper strips on top of the kindlings.
4. Cover the newspaper with more kindlings and small pieces of dry wood.
20