Download GWS-090E - Williamson
Transcript
GWS-090E Gas-Fired Water Boiler – Boiler Manual 1 Prepare boiler location Clearances Service clearances 1. Provide minimum clearances for cleaning and servicing the boiler and for access to controls and components as listed in Table 1 below: 2. Provide at least screwdriver clearance to jacket front panel screws for removal of front panel for inspection and minor service. If unable to provide at least screwdriver clearance, install unions and shutoff valves in system so boiler can be moved for servicing. Table 1 Minimum service clearances continued Residential garage installations Take the following special precautions when installing the boiler in a residential garage. If the boiler is located in a residential garage, per ANSI Z223.1, paragraph 5.1.9: • Mount the boiler a minimum of 18 inches above the floor of the garage to assure the burner and ignition devices will be no less than 18 inches above the floor. • Locate or protect the boiler so it cannot be damaged by a moving vehicle. Flooring and foundation Flooring The GWS-090E boiler is approved for installation on combustible flooring, but must never be installed on carpeting. Do not install boiler on carpeting even if foundation is used. Fire can result, causing severe personal injury, death or substantial property damage. Foundation Minimum clearance to combustible materials 1. Hot water pipes must be at least ½” from combustible material. 2. Vent pipe must be at least 2 inches from combustible material except where otherwise noted in GWS Venting Manual. Figure 1 Minimum clearances in small spaces 1. Provide a solid brick or minimum 2-inch thick concrete foundation pad if any of the following is true: • • floor can become flooded. the boiler mounting area is not level. 2. See Table 2, below, for minimum foundation dimensions. Table 2 Minimum foundation size Boiler model number Minimum foundation length Minimum foundation width GWS-090E 25” 18” Small space installations 1. When the boiler is located in a closet or small space, provide clearances no less than those shown in Figure 1. The clearances are required to any surface, whether combustible or non-combustible. Part Number 550-110-737/1108 3