Download CT2001 Touchscreen Programmable Thermostat
Transcript
CT2001 Touchscreen Programmable Thermostat Table 9. Sequence of Operation for Heat Pump Systems. System Setting Fan Setting Call for Action OFF AUTO None O/ B COOL AUTO None O/ B COOL or AUTO AUTO Stage 1 Cooling Y, G, O/B COOL or AUTO AUTO Stage 1 and Stage 2 Cooling HEAT AUTO None HEAT or AUTO AUTO Stage 1 Heating Y, G, O/B HEAT or AUTO AUTO Stage 1 and Stage 2 Heating Y, AUX , G, O/B HEAT or AUTO a AUTO Stage 1, 2 and 3 Heating Energize Terminals Y, a None a None a Cool On d Y2 , G, O/B a a O/B Heat On a Aux Heat On e Y, Y2 , AUX , G, O/B Cool On None a c d Screen Message a a Em. HEAT AUTO None L, O/B Em. HEAT AUTO Stage 1 Heating E, G, L, O/B Em. HEAT AUTO Stage 1 and Stage 2 Heating E, AUX, G, L, O/B Aux Heat On None a Heat On a Aux Heat On Configure O/B in Installer Setup. Based on last piece of equipment called (cooling = O or heating = B). cIf Installer Setup System Type is set to 2Heat/1Cool Heat Pump with Auxiliary Heat. dIf Installer Setup System Type is set to 3Heat/2Cool Heat Pump with Auxiliary Heat. eThis terminal does not energize if Installer Setup System type is set to 2 Heat/2 Cool Heat Pump with no Auxiliary Heat. 89