Download Compex Systems SA33-3285-02 Network Card User Manual
Transcript
force=yes/no If an array is using a fast-write cache that is failing, you must specify this attribute as yes to allow the fast-write cache to be disabled. | Hot Spare Pool Creation and Change Attribute You can specify the following attribute with the -a option when you are using the ssaraid command with the -C or -H option to create or change a hot spare pool: minimum_spares(default=0) This attribute determines the minimum number of hot spare disk drives that must be in this hot spare pool to prevent a hot spare pool error from being logged. Physical Disk Drive Change Attributes | | | | This section describes: | | | Change Attribute for Hot Spare Disk Drives Only | | | spare_pool (default=pool_A0 or pool_B0, as determined by the network ID) If you set this attribute, the hot spare disk drive is assigned to the specific hot spare pool. | | | Change Attribute for Array Member Disk Drives Only | | | | | | spare_pool (default=pool_A0 or pool_B0, as determined by the network ID) If you set this attribute, the array member disk drive is assigned to the specific hot spare pool. If the spare_preferred array attribute is set to true for the array to which this disk drive belongs, and this disk drive fails, a hot spare disk drive (if available) is selected only from the hot spare pool to which this disk drive is assigned. | | | | | | | | If the spare_preferred array attribute is set to false for the array to which this disk drive belongs, and this disk drive fails, a hot spare disk drive (if available) is selected from the hot spare pool to which this disk drive is assigned. If no hot spare disk drive is available in that pool, a hot spare disk drive is selected from the default hot spare pool for that SSA loop (Pool A0 or B0). If no hot spare disk drive is available in the default hot spare pool, a hot spare disk drive is selected from any other hot spare pool that contains a hot spare disk drive. v Change attribute for hot spare disk drives only v Change attribute for array member disk drives only v Other change attributes for physical disk drives You can specify the following attribute with the -a option only when you are using the ssaraid command with the -H option to change a hot spare disk drive: You can specify the following attribute with the -a option only when you are using the ssaraid command with the -H option to change an array member disk drive: Chapter 12. Using the SSA Command Line Interface for RAID Configurations 249
Related documents
User's Guide and Maintenance Information
86A161EV03-Power6 - SAS RAID Controller for
IBM SG24-5131-00 User's Manual
IBM RS/6000 User's Manual
User's Guide - ps-2.kev009.com, an archive of old documentation
Service Guide
IBM SY33-0193-00 User's Manual
Fisher-Price 78537 Motorized Toy Car User Manual
IBM 6C1 User's Manual
Compex Advanced SerialRAID Adapters SA33-3285-02 Installation guide