MAINTENANCE
MANUAL CONTROL SWITCH REPLACEMENT
1) Unplug the power source.
7) Remove the heat shield from the ECS box by undoing the 2
screws.
2) Open the bottom louver.
3) Remove the 3 screws that secure the manual control louver bracket
to the louver.
ECS Box
Heat Shield
8) Remove the ECS box cover by undoing the 3 screws.
4) Remove the louver bracket from the manual control box by undoing
one screw.
9) Unplug in the CAT5 cable of the manual control box from the connector in the ECS box.
Louver Bracket
Manual Control Box
5) Remove the valve heat shield by undoing the 2 screws.
10) Plug the replacement manual control switch CAT5 cable into the
connector in the ECS box.
Valve Heat Shield
11) Re-install the cover on the ECS box. Ensure to fit the rest of the cable
into the groove in the ECS box.
12) Re-install the heat shield on the ECS box.
6) Pull out the ECS box by carefully lifting it up off the velcro.
13) Put the ECS box back in place under the firebox.
14) Reverse steps 5 to 1.
ECS Box
Regency® PG36-4 Gas Log Fireplace