Download Dyna CSADX3200 Specifications
Transcript
SPECIFICATIONS MODEL Generator Surge Watts Continuous Watts AC Volts AC AMPS DC Volts DC AMPS Receptacles NEMA 5-15 (120V) NEMA 5-30 (120V) 12 Volt DC Engine Size Model TYpe Fuel Capacity Fuel Consumption full Load Starting System Stop System Low Oil Shutdown Muffler Complete Unit Weight (dry) Dimensions LxWxH Owner Must Provide Fuel Oil Type Oil Capacity DX3200 CSADX3200 3200 2800 120 23.3 12 10 3200 2800 120 23.3 12 10 4 2 1 1 1 5H P 5H P FA210 FA210 See Engine For Type 3/4 GAL 3/4 GAL 0.75 glhr 0.75 glhr Recoil Switch on Engine Shroud Standard Standard Muffler with Spark Arrestor 99 LBS 24x15~14 99 LBS 24x15x14 the engine and the generator. Small compartments will also develop hot spots where there is very little air flow and may cause a fire. 3. DO NOT attempt to operate this unit at 50 cycles. These units are designed and governed to operate at 60 Cycles only. Special units are available for 50 cycle operation. UNIT CAPABILITIES 1. Generator Connections - These generators are equipped with a single output power winding. This design will give the owner full rated generator output from a SINGLE 120 volt outlet. The battery charging circuit on the DX3200 is a center tapped off the standard 120 volt winding. On the CSADX3200 the battery charging circuit is separate winding on the armature. This output is then run through a half wave bridge rectifier where the current is changed from AC to pulsing DC current. The open circuit charging voltage as measured with a DC meter or a volt-ohm meter will read approximately seven (7) volts. The peak voltage will be over 16 volts in order to charge the battery. When the generator is connected to a 12 volt battery, the battery level voltage will immediately increase about 0.5 volts showing that the battery is being charged. A DC ammeter in series with the generator output will indicate a current reading approximately equal to the DC nameplate rating if the battery is discharged. Unleaded Gasoline SAE30 SC Class. See engine manual for additional info. .64 US qt. .64 US qt. INTENDED USES 1. These engine generator sets have been designed for portable use. Receptacles are provided in the control panel on the generator for you to plug in your loads (portable appliances and tools). These generators are designed with full power capabilities. See unit capabilities for further explanation. 2. These units require large quantities of fresh air for cooling of both the engine and the generator. Fresh air is drawn from both the engine end and the generator end and is exhausted at the center of the unit. For safety, long life and adequate performance, these units should never be run in small compartments without positive fresh air flow. RESTRICTED USES 1. DO NOT remove from the cradle assembly. Removal of the generator from the cradle assembly. may cause excessive vibration and damage to the engine generator set. 2. DO NOT install and operate these portable generators in small compartment. (i.e. generator compartment of vehicles, motor homes or travel trailers) These compartments will not allow enough free flow fresh air to reach the engine generator set for cooling and will allow the unit to overheat damaging both FIG B1 The following currents (measured in amps) are produced at 120 volts and 240 volts for models shown. AMPS @ 120 VOLT RECEPTACLE ID MODEL DX3200 CSADX3200 23.3 12 VOLT '"'