Download Proheat M80 Service manual
Transcript
4.1.6 (5 Flashes) VOLTAGE Diagnostic Code 5 Indicates that the supply voltage to the G-II PCM is outside the operating range for more then 10 seconds. Operating Range: • 12 volt PROHEAT – 10 to 16 volts. • 24 volt PROHEAT – 18 to 32 volts. Troubleshoot the Voltage diagnostic code based on: 1. Low voltage. • Voltage supply is below the rated requirement. • Poor or faulty electrical connections. • Voltage supply source is OK. Voltage drop due to high amperage load while the PROHEAT is operating or trying to operate. 2. High voltage. • Voltage supply is above the rated requirement while the vehicle engine is running. VOLTAGE: Step 1 (5 Flashes) VOLTAGE: Step 2 (5 Flashes) High Voltage – Check: The vehicle charging system. Consult the OEM for service requirements. Low Voltage – Check: a) System voltage supply source. b) Wiring harnesses and connection points. Procedure – Low voltage testing: a) Inspect the wiring harnesses and connections for corrosion and proper fit. Clean if necessary. b) Using a multimeter set for voltage, measure across the positive and negative battery terminals or at the supply source. If the voltage is below the required voltage, service the batteries and/or charging system as per OEM supplier recommendations. If the voltage level is within the operating range, go to item 'c'. TO PROHEAT Figure 4-27: Voltage Measurement. 4-26 PROHEAT M-SERIES G-II PCM SERVICE MANUAL