Download Danfoss VLT 6000 HVAC Technical data
Transcript
VLT® 6000 HVAC 606 - 614 Data log Value: Description Data log: Digital input Control word Status word Reference Feedback Output frequency Output voltage Output current DC link voltage Display text (LOG: DIGITAL INP) (LOG: BUS COMMAND) (LOG: BUS STAT WD) (LOG: REFERENCE) (LOG: FEEDBACK) (LOG: MOTOR FREQ.) (LOG: MOTOR VOLT) (LOG: MOTOR CURR.) (LOG: DC LINK VOLT) Function: With these parameters, it is possible to see up to 20 saved values (data logs) - [1] being the most recent and [20] the oldest log. When a start command has been given, a new entry to the data log is made every 160 ms. If there is a trip or if the motor has stopped, the 20 latest data log entries will be saved and the values will be visible in the display. This is useful, e.g. in the case of service after a trip. The data log number is given in square brackets; [1] EXT. REFERENCE, % 63.0 % SETUP 1 606 DATALOG: DIGITAL INPUT [0] 40 Data logs [1]-[20] can be read by first pressing [CHANGE DATA], followed by the [+/-] keys to change data log numbers. Parameters 606-614 Data log can also be read out via the serial communication port. Description of choice: Parameter 606 Data log: Digital input input:: This is where the latest log data are shown in decimal code, representing the status of the digital inputs. Translated into binary code, terminal 16 corresponds to the bit to the extreme left and to decimal code 128. Terminal 33 corresponds to the bit to the extreme right and to decimal code 1. The table can be used, e.g., for converting a decimal number into a binary code. For example, digital 40 corresponds to binary 00101000. The nearest smaller decimal number is 32, corresponding to a signal on terminal 18. 40-32 = 8, corresponds to the signal on terminal 27. Unit Decimal Decimal Decimal % Par. 414 Hz Volt Amp Volt Range 0 - 255 0 - 65535 0 - 65535 0 - 100 -999,999.999 - 999,999.999 0.0 - 999.9 50 - 1000 0.0 - 999.9 0.0 - 999.9 Terminal 16 17 18 19 27 29 32 33 Decimal number 128 64 32 16 8 4 2 1 Parameter 607 Data log: Control word word:: This is where the latest log data are given in decimal code for the control word of the VLT frequency converter. The control word read can only be changed via serial communication. The control work is read as a decimal number which is to be converted into hex. See the control word profile under the section Serial communication in the Design Guide. Parameter 608 Data log: Status word word:: This gives the latest log data in decimal code for the status word. The status word is read as a decimal number which is to be converted into hex. See the status word profile under the section Serial communication in the Design Guide.. Parameter 609 Data log: Reference Reference:: This gives the latest log data for the resulting reference. Parameter 610 Data log: Feedback Feedback:: This gives the latest log data for the feedback signal. Parameter 611 Data log: Output frequency frequency:: This gives the latest log data for the output frequency. Parameter 612 Data log: Output voltage voltage:: This gives the latest log data for the output voltage. Parameter 613 Data log: Output current current:: This gives the latest log data for the output current. Parameter 614 Data log: DC-link voltage voltage:: This gives the latest log data for the intermediate circuit voltage. ★ = factory setting. ( ) = display text [ ] = value for use in communication via serial communication port MG.60.B1.02 - VLT is a registered Danfoss trade mark 143 Programming Parameter no. 606 607 608 609 610 611 612 613 614