Download Sharp IQ-8000 Installation manual
Transcript
9.3 IQ-800 Features (IQ-400 plus 4-Reader Expansion Module) 9.3.1 Two Auxiliary (Powered) Outputs (cc# 89, 90) 8 Reader Ports: (Wiegand electrical interface for PCSC and OEM card readers) (Readers a-h) 8 Form C Door Strike Outputs (2.0 amps @ 12/24 VDC continuous power) 8 Door Left Open Outputs (or 8 External Shunt Options) 8 Supervised Door Senses (17, 19, 21, 23, 25, 27, 29, 31) 5 Supervised User-Defined (Auxiliary) Sense Inputs (S14, S120, S121, S122, S123) 8 Supervised Request to Exit Inputs (16, 18, 20, 22, 24, 26, 28, 30) Battery Backed Clock Calendar Flash RAM 128K standard (up to 256K) Battery-Backed RAM 256K standard (up to 512K) LEDs for: Power, alarm, on-line diagnostics Reader Data [Error code, Door Status] Unsupervised Tamper detect (S13) 9.3.2 System Capacities Cardholder Capacity: Time Periods: Holiday Time Periods: Holiday List: History Transactions: Enclosure Dimensions: Weight: Power: Draw: Temperature: Communications: 8,000 (20,000 w/ Memory Expansion) 32 32 366 Days (Leap Year) 4,000 regardless of memory size 18”H x 11.5”W x 6”D (45.7cm x 29.2cm x 15.2cm) 38 lbs. (17.3kg) 12VDC 3 amp @ 12VDC 32°F to 115°F (0°C to 46°C) RS485 standard RS232 standard Dial-up standard Ethernet optional 9.3.3 Electrical Ratings Power: Draw: Relay Contacts 12VDC 660mA @ 13.65V 2 A @ 24 VDC Data0/Data1 5 Vdc @ 0 mA for Logic 1 0 Vdc @ 5mA for Logic 0 Alarm Point Voltage & Tamper Voltage 5.0 Vdc @ 0.0 mA when Sense Input is in Open Circuit Physical State. 0.0 Vdc @ 5.0 mA when Sense Input is in Short Circuit Physical State. 1.6 Vdc @ 3.4 mA when Sense Input is in Alarm Physical State. 0.9 Vdc @ 4.1 mA when Sense Input is in Normal Physical State. Page xci of 110 IQ-400 Installation Manual 33-10057-001-C