Download Roland R-1000 Technical data
Transcript
Manual Double Sheet Detector R1000 series E20 B0046991 / Rev. 1.6 Electrical installation 5.2.2 Allocation of connectors at the E20-4P RS232 Power PG9 SPS / PLC PG16 Sensor 1 Sensor 2 PG11 EMV PG11 EMV Sensor 3 Sensor 4 PG11 EMV PG11 EMV Fig. 31: Allocation of connectors at the E20-4P Pos : 40 /D oppel blech/Geräte/E20/5 Elektrisc he Installati on/Ansc hlus s an Betriebs erde @ 1\mod_1192713625531_501.doc @ 5096 @ 2 @ 1 5.3 Connection to the grounding of the machine The enclosure of the R1000 has an M6 threaded screw as grounding connection. This screw must be connected to the earth ground of the equipment with a copper wire gauge of at least 1.5 mm² cross section. Attention The positive supply voltage +24 VDC should not be connected to machine ground. Pos : 41 /D oppel blech/Geräte/E20/5 Elektrisc he Installati on/Verdr ahtungspl äne und Kl emmenbeleg ung @ 1\mod_1192448670343_501.doc @ 4820 @ 2333333 @ 1 64 ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33