UK SD – FIRE ALARM This zone works just like a fire zone. In contrast to a fire zone, the connected fire alarms can be reset by briefly switching off the power supply and no alarm is triggered. However, the reset must be made via a switch output. The program menu can be exited only when this zone is closed. 13 General terms ZONE A zone consists of one or more detectors connected to the burglar alarm panel via an input CCT. A zone is considered to be opened or triggered if the electric circuit within CCT is interrupted by a detector (motion sensor, magnetic contact,…) (for NC), or if the resistance value changes (for DEOL). A zone is considered as closed or at rest is the electric circuit is closed within CCT (for NC), or if the line voltage from the alarm centre is within the right parameters (for DEOL). KM – KEY SWITCH PULSE A key switch (pulsed) can be connected to the burglar alarm panel. Any change to this zone changes the state of the alarm centre from active to inactive or from inactive to active (following a timeout of the delay time). FK – BLOCK LOCK A key switch (permanent) can be connected to the burglar alarm panel. Any change to this zone changes the state of the alarm centre from active to inactive or from inactive to active (following a timeout of the delay time). Note that you can operate the alarm centre only via the key switch. If the state is unclear, e.g.: the key switch is closed, and deactivated at the control unit, the alarm centre can return to active state. BURGLAR ALARM PANEL ACTIVATED When the burglar alarm panel is active, it monitors all zones for changes to the line voltage and triggers a local alarm and optionally an external alarm. BURGLAR ALARM PANEL DEACTIVATED When the burglar alarm is active, it monitors only zones that are always active, such as 24-hour zones, technical zones, and burglar and fire alarms. An alarm triggered by one of these zones usually results in an internal alarm. AM – ANTI-MASK The anti-mask function is supported by some motion sensors and works as a cover (tamper) protector. The alarm centre is informed by a separate output on the sensor that the sensor is covered. This problem is then reported to the appropriate alarm zone. INTERNALLY/EXTERNALLY ACTIVATED In addition to the complete activation of the burglar alarm panel, you can also activate individual areas (B, C, D). This means that areas can be activated and protected even if you are at home. This type of activation is known as internal. FB – FORBIKOBLER This zone is connected to an external code lock or an access control device. This zone works like a regular entry/exit zone. If this zone is triggered during the exit time, the exit time is ended immediately and the burglar alarm panel is activated. If this zone is triggered when the burglar alarm panel is active, it starts the entry delay. INTERNAL ALARM In the case of an internal alarm, only the buzzers of the control units and the optional loudspeakers are activated. LOCAL ALARM In the case of a local alarm, the connected combination signalling devices (flashlight and siren) are also activated. EXTERNAL ALARM In the case of an external alarm, not only the acoustic and visual signalling devices are activated: the alarm is also transmitted via telephone. 24