Download Excell DIGITAL HIGH PRECISION WEIGHING SCALES Specifications

Transcript
EXCELL PRECISION CO., LTD.
© Excell Precision Limited 2005.
All rights reserved Worldwide.
The information contained herein is the property of Excell Precision Limited and is supplied
without liability for errors or omissions. No part may be reproduced or used except as
authorised by contract or other written permission. The copyright and the foregoing
restriction on reproduction and use extend to all media in which the information may be
embodied.
SK-VET V1.0
SME300000067
EXCELL PRECISION CO., LTD.
TABLE OF CONTENTS
BEFORE USING THE SCALE.......................................................................................... 2
SAFTY INSTRUCTIONS................................................................................................... 2
PREPARING TO USE THE SCALE.................................................................................. 3
CHAPTER 1 FEATURES AND SPECIFICATIONS .......................................................... 4
CHAPTER 2 DISPLAY ...................................................................................................... 6
CHAPTER 3 KEYBOARD FUNCTION ............................................................................. 7
CHAPTER 4 SERVICE MODE ACCESS.......................................................................... 8
.................................................................... 9
4-1. CAPACITY CONFIGURATION
4-2. W EIGHT CALIBRATION
......................................................................... 12
4-3. FUNCTION SETTINGS
........................................................................... 13
................................................................ 14
4-3-1 Environment Settings
4-3-2 Buzzer Type
4-4.SPAN CALIBRATION
.............................................................................. 16
.......................................................................................... 17
4-5.GRAVITY COMPENSATION .................................................................................................... 18
CHAPTER 5 ADVANCED FUNCTIONS ......................................................................... 19
5-1. AUTO POWER OFF AND BACKLIGHT SETTINGS ...................................................................... 19
APPENDIX ...................................................................................................................... 22
SK-VET V1.0
1
SME300000067
EXCELL PRECISION CO., LTD.
BEFORE USING THE SCALE
Thank you for purchasing an EXCELL Electronic Digital Scale. In order to use the
scale properly, please read this User Manual carefully before use. If you have a
problem concerning the scale, please contact your supplier.
1. Please keep scale in a cool and dry place. Do not store at high temperatures.
2. Do not allow any liquids to come into or contact with the scale. If it is happened, wipe the
scale dry with a cloth.
3. Avoid objects impacting with the scale. Do not drop loads onto the scale or subject the
weigh pan to any strong shock loads.
4. The load placed on the weigh pan must not exceed the maximum weighing capacity of
the scale.
5. If the scale is not going to be used for some time, please clean it and store it in a plastic
bag in dry conditions. A desiccant sachet may be included to prevent moisture build up.
6. Do not mix different types of dry battery or mix used dry batteries with new dry batteries.
SAFTY INSTRUCTIONS
1. Please confirm that the electrodes “+”、“-” are on the right position.
2. To avoid the electric leakage, please do not place the battery in high temperature, or try
to disassemble it.
3. Please do not mix different type of dry cells。
4. Please do not use new and old dry cells at the same time.
5. Please do not leave the empty dry cells in the scale.
SK-VET V1.0
2
SME300000067
EXCELL PRECISION CO., LTD.
PREPARING TO USE THE SCALE
1. For accurate weight readings locate the scale on a firm level surface free from vibrations.
2. Avoid operating the scale in direct sunlight or drafts of any kind.
3. Remove any weight that might be on the weigh pan before the scale is switched on and
avoid leaving weight on the pan for long periods of time.
4. Once the scale has been switched on, it will go through a LCD display test and then
re-zero to be ready for use.
5. The scale requires 15~20 minutes warming up the machine before operation to ensure
best accuracy.
6. Please note when
symbol appears on the screen, the dry batteries need to be
replaced.
7. All goods weighed should be placed in the centre of the weigh pan for accurate weighing.
The overall dimensions of the goods being weighed should not exceed the dimension of
the weigh pan.
SK-VET V1.0
3
SME300000067
EXCELL PRECISION CO., LTD.
CHAPTER 1 FEATURES AND SPECIFICATIONS
Features:
n
Multi-function operation: Fast weighing operation; Full range tare; Auto power-off; Weight
hold feature.
n
Dual-weighing units: Pound (lb) and kilogram (kg).
n
User-friendly design: Auto calibration; Large LCD display (digit height 12mm x 25mm);
Gravity compensation; Low battery warning indicator; Double over-load protection.
n
Dual-power source: The power source can either be from AC / DC or dry batteries.
Option:
n
LED display backlight
Specifications:
Model
SK-VET-150
SK-VET-300
Operating Temperature
Power Source
Weight pan Size
Capacity
Min. Cap.
Division Resolution
150kg
1kg
50g
1/3000
300kg
2kg
100g
1/3000
0°C ~ 40°C (32°F ~ 104°F)
4 x AAA dry battery or AC mains adaptor DC 9V
570 x 900 mm (Iron platter)
Product Package:
n
Scale 1 off
n
AC adapter 1 off
n
User manual 1 off
n
Please contact to your supplier, if any of the items described above is missing.
n
Dry batteries are not included in the product package.
SK-VET V1.0
4
SME300000067
EXCELL PRECISION CO., LTD.
Selectable Weight Units and Piece Unit:
Kilogram
(kg)
Gram
(g)
Pound
(lb)
Pound/Ounce (lb, oz)
Ounce
(oz)
1g
1g
1g
1g
1g
=
=
=
=
=
0.001 kg
1g
0.002204623 lb
0.03527396 oz
0.03527396 oz
Error Messages:
⇒ The EEPROM memory is not working correctly.
⇒ Zero is higher than the zero range when switching the scale on.
⇒ Zero is lower than the zero range when switching the scale on.
⇒ A/D value is unstable. When switching the scale on or pressing the
ON/ZERO
key
or the TARE key, the A/D value is unstable for at least 20 seconds.
⇒ A/D value is less than -31250.
⇒ A/D IC malfunction (cannot read A/D value). The load cell may not be connected to
the scale correctly.
⇒ A/D value is higher than +31250.
⇒ The weight of the object is over the maximum capacity + 9 divisions.
⇒ After calibration the displayed resolution is greater than the internal resolution.
⇒ The gravity value is outside the range 9.772 ~ 9.829.
⇒ Error setting.
⇒ The weight value is greater than the zero range, when re-zeroing the
scale.
⇒ The weight value is below the zero range, when re-zeroing the scale.
SK-VET V1.0
5
SME300000067
EXCELL PRECISION CO., LTD.
CHAPTER 2 DISPLAY
1
2
3
TARE: “Tare” indication.
ZERO: “Zero” indication.
► 1: Kilogram (kg), the 1st unit indication.
► 2: Pound (lb), the 2nd unit indication.
► 3: Hold mode indication.
: “Low Battery” indication.
SK-VET V1.0
6
SME300000067
EXCELL PRECISION CO., LTD.
CHAPTER 3 KEYBOARD FUNCTION
1.
2.
OFF
: The key to switch the scale off.
ON
ZERO
: ON/ZERO key. When the scale is off, press the key to switch it on. When the
scale is switched on, with the weigh pan empty, if the display is not showing zero, press this
key to zero (balance) the scale.
v Zero range: ± 2% of full scale.
TARE
3.
: TARE key. Press the key to deduct the weight of the container.
v The tare key is not functional when the weight value shown on the display is negative or
over the full scale capacity.
UNITS
4.
: Units key.
Press the key to select the desired weight unit.
HOLD
5.
SK-VET V1.0
: Shift between the normal weighing mode and the Animal Weight Hold mode.
7
SME300000067
EXCELL PRECISION CO., LTD.
CHAPTER 4 SERVICE MODE ACCESS
v Set the jumper SWA1 on the main board to the ADJ position (EEPROM
UNLOCKED). Press and hold the TARE key, followed by pressing the
key.
ON/ZERO
Release the ON/ZERO key first and then the TARE key to
enter the service mode; the display shows
.
v Set the SWA1 jumper back to the LOCK position when service configuration is
completed.
v If the SWA1 jumper is set to its LOCK position during calibration, the scale exits
the service mode automatically.
Press the UNITS key
Press the ON/ZERO key
Press the UNITS key
Press the ON/ZERO key
Press the UNITS key
Press the ON/ZERO key
⇒
Capacity Configuration
⇒ Weight Calibration
⇒
SK-VET V1.0
Function Settings
8
SME300000067
EXCELL PRECISION CO., LTD.
4-1. Capacity Configuration
ON/ZERO
Press the TARE key
⇒ Increment digit (from 0 to 9)
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
Input the parameter “01” to
enter the capacity
configuration
The display shows the maximum capacity
+ 1 division and the weight unit set last
time for 2 seconds.
Press the TARE key
.
►
Weight unit or piece unit
setting
Example:
Two weight units “kg” & “lb”, with “kg” as
the units used for weight calibration.
Refer to “Note 1”
Press the TARE key
Enter the maximum
capacity
Refer to “Note 2”
Example:
03000 ⇒ 300.0 kg
Press the TARE key
NEXT
PAGE
SK-VET V1.0
9
SME300000067
EXCELL PRECISION CO., LTD.
Refer to “Note 3”
Example:
1 ⇒ Division size
1 ⇒ The number of decimal places
0 ⇒ range setting
Press the TARE key
The display shows the max. capacity of the
scale + minimum division and the unit
weight for 2 seconds.
.
Input the parameter “00”
Press the TARE key to
complete the capacity
configuration
SK-VET V1.0
10
SME300000067
EXCELL PRECISION CO., LTD.
NOTE 1 The users can set up the different weight units in various orders according to their
preference, and the amount of the chosen weight units can be up to 4.
(a) (b) (c)
(e)
(a) ⇒ The first weight unit (only “kg”, or “lb” are available to choose from).
(b) ⇒ The second weight unit (select one of the parameters listed below).
(c) ⇒ The third weight unit (select one of the parameters listed below).
(e) ⇒ The amount of the weight units selected (select one of parameters 1 ~ 3).
Parameter descriptions:
\
0 ⇒ kg
1⇒g
2 ⇒ lb
4 ⇒ lb / oz
5 ⇒ oz
Hints and Tips:
Ø When the first unit is set to lb, the second unit will be kg or g.
For example:
Select two weight unit kg and lb. when choosing kg as calibration weight unit, please input
02002
NOTE 2 Enter the maximum capacity of the scale, total 5 digits
(f) ( g ) ( h ) ( i) (j)
For example:
300.0 kg ⇒ Key in 03000
NOTE 3 Set the division size and decimal point position to determine the display resolution
(k) ( l ) ( m )
(k) ⇒ Division size (select 1, 2, or 5)
(l) ⇒ The number of decimal places (0 ~ 5)
For example:
15.000 kg ⇒ enter 3
1500.0 g ⇒ enter 1
(m) ⇒ range setting (select one of parameters 0, 1, or 2)
For example:
0 &1 ⇒ full range, 2 ⇒ dual range (divided at 1/2 of the full scale)
SK-VET V1.0
11
SME300000067
EXCELL PRECISION CO., LTD.
4-2. Weight Calibration
ON/ZERO
Press the TARE key
⇒ Increment digit (from 0 to 9)
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
Input the parameter “01”
The display shows the calibration weight
value and the weight unit set at the first
position.
Press the TARE key
►
.
Unload the weigh pan
Press the TARE key
When the weight reading is stable the
display shows the calibration weight value.
♦ The scale copies and saves the local
gravity value automatically.
►
When stable
The calibration weight value can be
changed to match the needs of customer
►
.
Place full load (300kg in this
example) on the weigh pan
then press the
TARE key
The scale shows the calibration weight
value.
The buzzer sounds “beep, beep, beep”
when the weight reading is stable.
►
.
Remove the weight from the
weigh pan and press any key
to exit the setting.
Input the parameter “00”
Press the TARE key
to complete the
calibration
SK-VET V1.0
12
SME300000067
EXCELL PRECISION CO., LTD.
4-3. Function Settings
Press the TARE key
Input a parameter 00, 01, or
02.
After inputting “00”,
Press the TARE key
ON/ZERO
to return to the upper level
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
⇒ Increment digit (from 0 to 9)
⇒ Return to the upper menu level
⇒ Environment settings
⇒ Buzzer type
SK-VET V1.0
13
SME300000067
EXCELL PRECISION CO., LTD.
4-3-1 Environment Settings
Returning to zero point setting
Displays the current setting
Returning to zero point setting
Use the ON/ZERO key to input a
parameter
Default setting = 0
0 ⇒ show all
5 ⇒ cover 5 d
1 ⇒ cover 1 d
6 ⇒ cover 6 d
2 ⇒ cover 2 d
7 ⇒ cover 7 d
3 ⇒ cover 3 d
8 ⇒ cover 8 d
4 ⇒ cover 4 d
9 ⇒ cover 9 d
♦ The function is active when the weight
value is over 1/3 of full capacity
Press the TARE key
Use the ON/ZERO key to
input a parameter
Press the TARE key
Digital switch &stable range parameter setting
Displays the current setting
Digital switch &stable range parameter setting
Use the ON/ZERO key to input a parameter
Default setting = 0
Parameter 0 ~ 9 ,
The greater the figure, the more stable the
displayed weight will be
Use the ON/ZERO key
to input a parameter
Press the TARE key
Filter parameter setting
Displays the current setting
Use the ON/ZERO key to
Filter parameter setting
Use the ON/ZERO key to input a parameter
Default setting = 5
Parameter 0 ~ 9,
input a parameter
The greater the figure, the faster the filter
will react. Consequently, the weight may be
less stable.
NEXT
PAGE
ON/ZERO
SK-VET V1.0
14
⇒ Increment digit (from 0 to 9)
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
SME300000067
EXCELL PRECISION CO., LTD.
Stable range parameter setting
The display shows the current setting.
Cont.
Press the TARE key
Stable range parameter setting
Use the ON/ZERO key to input a parameter
Default setting = 1
0 ⇒ No limitation
1 ⇒ Less than 1/4 division/sec
2 ⇒ Less than 1/2 division/sec
3 ⇒ Less than 2/3 division/sec
4 ⇒ Less than 1 division/sec
Use the ON/ZERO key to
input a parameter
Press the TARE key
Re-zero range setting
The display shows the current setting
Use the ON/ZERO key
Re-zero range setting
Use the ON/ZERO key to input a parameter
Default setting = 02
00 ⇒ No limitation
01 ⇒ ±1%
02 ⇒ ±2%
to input a parameter
15 ⇒ ±15%
Press the TARE key
Zero range setting
The display shows the current setting
Use the ON/ZERO key to
Zero range setting
Use the ON/ZERO key to input a parameter
Default setting = 20
00 ⇒ No limitation
01 ⇒ ±1%
02 ⇒ ±2%
input a parameter
Press the TARE key
50 ⇒ ±50%
Key in the parameter “00”
Press the TARE key
SK-VET V1.0
ON/ZERO
15
⇒ Increment digit (from 0 to 9)
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
SME300000067
EXCELL PRECISION CO., LTD.
4-3-2 Buzzer Type
Press the TARE key
Buzzer type
The display shows the current setting
Use the ON/ZERO key to
Buzzer type
Use the ON/ZERO key to key in a parameter
0 ⇒ Pulse signal
(AC buzzer, PT-134OP, 4KHz)
key in a parameter
1 ⇒ Continuous signal
(DC buzzer, UIC-4201)
Press the TARE key
Key in the parameter “00”
ON/ZERO
Press the TARE key
SK-VET V1.0
16
⇒ Increment digit (from 0 to 9)
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
SME300000067
EXCELL PRECISION CO., LTD.
4-4.Span Calibration
v Set the jumper SWA1 on the main board to the ADJ position (EEPROM
UNLOCKED). Press the ON/ZERO key to enter the SPAN calibration mode;
the display shows
.
v Set the jumper SWA1 back to the LOCK position, after completing the
calibration.
v If the jumper SWA1 is set back to the LOCK position during calibration, the
scale exits the service mode automatically.
Press the TARE key
Detect and save zero point in EEPROM
automatically.
The maximum capacity is displayed.
.
Place a load on the weigh
pan according to the weight
value show on the display,
then press
the TARE key.
.
The calibration data is saved in the
EEPROM
.
Remove the load from the
weigh pan.
ON/ZERO
.
⇒ Increment digit (from 0 to 9)
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
Set the jumper SWA1 to the LOCK position.
The scale returns to the weighing mode.
SK-VET V1.0
17
SME300000067
EXCELL PRECISION CO., LTD.
4-5.Gravity Compensation
Set the jumper SWA1 on the main board to the ADJ position. Press the
ON/ZERO
key to switch on the scale, and press the ON/ZERO key again before the display
resets back to zero. The scale enters the gravity compensation mode.
The display shows the current
compensation value
.
Key in the local gravity
value
.
Press the TARE key
The display shows and saves
the entered gravity value in
the EEPROM.
ON/ZERO
.
⇒ Increment digit (from 0 to 9)
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
Set the jumper SWA1 to the LOCK position
The scale returns to the weighing mode
v The gravity value must lie between those at the Equator and the Polar Regions.
Gravity value at the equator GE = 9.7803184558 m/sec2
Gravity value at the polar region GP = 9.8321772792 m/sec2
Taipei:
9.78914 m/sec2
Shanghai:
v The display shows error message
range (9.829 > gravity >9.772).
SK-VET V1.0
9.79585 m/sec2
, when the gravity value is NOT within the
18
SME300000067
EXCELL PRECISION CO., LTD.
CHAPTER 5 ADVANCED FUNCTIONS
5-1. Auto Power off and Backlight Settings
Switch on the scale, press the ON/ZERO and the HOLD keys together to enter the advanced
function settings mode. The display shows
。
The display shows the current setting
Auto power off timer setting
Use the ON/ZERO key to enter a parameter.
0 ⇒ No auto power-off
1 ⇒ When the scale is idle for 1 minute, the
scale automatically switches off
2 ⇒ When the scale is idle for 2 minutes, the
scale automatically switches off
Use the ON/ZERO key to
enter a parameter
Press the TARE key
19 ⇒ When the scale is idle for 19 minutes,
the scale automatically switches off
The display shows the current setting
Use the ON/ZERO key to
enter a parameter
Auto backlight setting
Use the ON/ZERO key.
on ⇒ Auto Backlight on
off ⇒ Auto Back light off
NEXT
PAGE
ON/ZERO
⇒ Increment digit (from 0 to 9)
TARE
⇒ Confirm / enter key
HOLD
⇒ Move the cursor to the right
Automatic Power-off Function
When the weight on weigh pan is less than 10d or remains steady for the set time, the scale
will automatically switch off.
v Automatic power-off is not functional when using an ac adaptor as the power source.
Therefore, auto power-off is active ONLY when using dry batteries as the power source.
Auto Backlight Function
When the weight is over 10d, the backlight is on. After the weight is stable for 10 seconds or
when the scale returns to zero, the backlight switches off.
SK-VET V1.0
19
SME300000067
EXCELL PRECISION CO., LTD.
Cont.
Hold function setting
LCD displays the last current setting
Press the TARE key
Hold function setting
Use the ON/ZERO key to
Use the ON/ZERO key to key in a parameter
enter a parameter
Default setting = 0
0 ⇒ Hold function disabled
1 ⇒ “Peak hold” mode
2 ⇒ “Stable hold 1” mode
3 ⇒ “Stable hold 2” mode
4 ⇒ “Animal weighing” mode
Press the TARE key
Refer to NOTE 4 to key in
parameters and then press
Back to the weighing
the TARE key
parameter setting
If
is selected, refer to
NOTE 4 to key in parameters
mode
= Hold function disabled.
= “Peak hold” mode (active when the weight on platter is over 10d)
The scale shows the maximum weight value detected from the continuously changing
weight values. Press any key to exit the hold function.
= “Stable hold” mode 1 (active when the weight on platter is over 10d)
When the scale becomes stable, the display shows the current weight value. Press any key
to exit the hold function.
= “Stable hold” mode 2 active when the weight on platter is over 10d)
When the scale becomes stable, the display shows the current weight value. Re-zero the
scale (weight below 10d) to exit the hold function.
= “Animal Weighing ” mode(active when the weight on platter is over 10d)
Refer to NOTE4 to key in the stabilization range and timer parameters. When the scale
becomes stable, the display shows the current weight value. Re-zero the scale (weight
below 10d) to exit the hold function.
SK-VET V1.0
20
SME300000067
EXCELL PRECISION CO., LTD.
NOTE 4
parameter setting (Animal Weighing mode)
(a) (b) (c) (d) (e)
(a) ⇒ Parameters 0~4 to set the stabilization timer
0: 0.5 second
1: 1 second
2: 2 seconds (default setting)
3: 4 seconds
4: 8 seconds
(b) (c) (d) (e) ⇒ Dynamic stabilization range setting: 0 ~ 100% (pre-set as 5%)
Example: To set the stabilization timer as 4 seconds and the range as 1.5%, key in 30015.
SK-VET V1.0
21
SME300000067
EXCELL PRECISION CO., LTD.
APPENDIX
7 SEGMENT DISPLAY CHARACTERS:
7 segments
Alphabet
Digit
letter
7 segments
letter
Alphabet
0
A
N
1
B
O
2
C
P
3
D
Q
4
E
R
5
F
S
6
G
T
7
H
U
8
I
V
9
J
W
K
X
L
Y
M
Z
SK-VET V1.0
22
7 segments
letter
SME300000067