Download Micrel KSZ8895 Specifications
Transcript
Micrel, Inc. KSZ8895MQ/RQ/FMQ Selection of Isolation Transformer(1) One simple 1:1 isolation transformer is needed at the line interface. An isolation transformer with integrated commonmode choke is recommended for exceeding FCC requirements at line side. Request to separate the center taps of RX/TX at chip side. The following table gives recommended transformer characteristics. Characteristics Name Value Turns Ratio Test Condition 1 CT : 1 CT Open-Circuit Inductance (min.) 350µH 100mV, 100kHz, 8mA Insertion Loss (max.) 1.1dB 0.1MHz to 100MHz HIPOT (min.) 1500Vrms Table 33. Transformer Selection Criteria Notes: 1. The IEEE 802.3u standard for 100BASE-TX assumes a transformer loss of 0.5dB. For the transmit line transformer, insertion loss of up to 1.3dB can be compensated by increasing the line drive current by means of reducing the ISET resistor value. 2. The center taps of RX and TX should be isolated for the low power consumption. The following transformer vendors provide compatible magnetic parts for Micrel’s device: Vendors and Parts Auto MDIX Number of Ports Vendors and Parts Auto MDIX Number of Ports Pulse H1664NL Yes 4 Pulse H1102 Yes 1 YCL PH406082 Yes 4 Bel Fuse S558-5999-U7 Yes 1 TDK TLA-6T718A Yes 1 YCL PT163020 Yes 1 LanKom LF-H41S Yes 1 Transpower HB726 Yes 1 Datatronic NT79075 Yes 1 Delta LF8505 Yes 1 Table 34. Qualified Magnetic Vendors Selection of Reference Crystal Chacteristics Value Units 25.00000 MHz <= ±50 ppm Load capacitance (max) 27 pF Series resistance (max ESR) 40 Ω Frequency Frequency tolerance (max) Table 35. Typical Reference Crystal Characteristics March 12, 2014 117 Revision 1.7