Download Cobra C6 Specifications
Transcript
Part 2 Specifications Model Covered in this Specification - NOTE: (*) C6D [1] Cooktop C6C [1] Cooktop C6B Cooktop 4 Open Burners. 2 Burners + 300mm Griddle. 600mm Griddle. C9D [1] C9C [1] C9B [1] C9A 6 Open Burners. 4 Burners + 300mm Griddle. 2 Burners + 600mm Griddle. 900mm Griddle. Cooktop Cooktop Cooktop Cooktop * - The burner operating pressure is to be measured at the manifold test point with two burners operating at full setting. The operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from when carrying out gas conversion, if required. (Refer to the ‘Gas Conversion Instruction Sheet’ for this appliance for further details). Gas Connection [1] - Open Burner Options:F - With Flame Failure Protection. - Standard Burners. Gas supply connection point is located at the rear of the appliance, approximately 130 mm from the right hand side and 630 mm from the floor. It is reached from beneath the appliance. (Refer to the ‘Dimensions’ section). General A heavy duty, high efficiency Cooktop for modular kitchens. It has a high option Cooktop / Griddle arrangement and is available on adjustable front feet and robust rear rollers. Five griddle options with 2 models of base unit are available. Fitted with 'Individual Flame Failure' Option (F) for each open burner. (Standard for UK - Optional for Non UK) Griddles are fitted with pilot, flame failure and piezo ignition as standard. These cooktops have an easy clean stainless steel external finish. Connection is ¾" BSP male thread (for all models). Gas Supply Requirements - Non - UK Only: Natural Gas LP Gas (Propane) Open Burner (each) Input Rate (N.H.G.C.) Griddle (each 300mm section) 22 MJ/hr 20 MJ/hr (20,000 Btu/hr) (18,956 Btu/hr) Supply Pressure Burner Operating Pressure Open Burner (each) 22 MJ/hr (20,000 Btu/hr) Griddle (each 300mm section) 20 MJ/hr (18,956 Btu/hr) 1.13 - 3.40 kPa (4.5” -13.5” w.c.) 2.75 - 4.50 kPa (11” -18.0”w.c.) 1.0 kPa (*) (4.0” w.c.) 2.6 kPa (*) (10.0” w.c.) Gas Connection ¾” BSP Male - UK Only: Heat Input (net) Gas Rate (net) Nominal Propane (G31) Open Burner Griddle (each) (each 300mm section) 4.6 kW 5.0 kW Reduced 1.7 kW 1.5 kW 1.5 kW 2.2 kW Nominal 0.53 m3/hr 0.53 m3/hr 0.36 kg/hr 0.39 kg/hr m3/hr m3/hr 0.12 kg/hr 0.17 kg/hr Reduced Supply Pressure Burner Operating Pressure Gas Connection Natural Gas (G20) Open Burner Griddle (each) (each 300mm section) 5.0 kW 5.0 kW 0.18 0.16 20 mbar 37 mbar 10 mbar (*) 28 mbar (*) ¾” BSP Male 3