Download Cobra C6 Specifications

Transcript
Part 2
Specifications
Model Covered in this Specification -
NOTE: (*)
C6D [1] Cooktop
C6C [1] Cooktop
C6B
Cooktop
4 Open Burners.
2 Burners + 300mm Griddle.
600mm Griddle.
C9D [1]
C9C [1]
C9B [1]
C9A
6 Open Burners.
4 Burners + 300mm Griddle.
2 Burners + 600mm Griddle.
900mm Griddle.
Cooktop
Cooktop
Cooktop
Cooktop
* - The burner operating pressure is to be measured
at the manifold test point with two burners
operating at full setting. The operating pressure
is ex-factory set, through the appliance regulator
and is not to be adjusted, apart from when
carrying out gas conversion, if required. (Refer
to the ‘Gas Conversion Instruction Sheet’ for this
appliance for further details).
Gas Connection
[1] - Open Burner Options:F - With Flame Failure Protection.
- Standard Burners.
Gas supply connection point is located at the rear
of the appliance, approximately 130 mm from the
right hand side and 630 mm from the floor. It is
reached from beneath the appliance. (Refer to the
‘Dimensions’ section).
General
A heavy duty, high efficiency Cooktop for modular
kitchens. It has a high option Cooktop / Griddle
arrangement and is available on adjustable front
feet and robust rear rollers. Five griddle options with
2 models of base unit are available. Fitted with
'Individual Flame Failure' Option (F) for each open
burner. (Standard for UK - Optional for Non UK)
Griddles are fitted with pilot, flame failure and piezo
ignition as standard. These cooktops have an easy
clean stainless steel external finish.
Connection is ¾" BSP male thread (for all models).
Gas Supply Requirements
- Non - UK Only:
Natural Gas
LP Gas (Propane)
Open Burner
(each)
Input Rate (N.H.G.C.)
Griddle
(each 300mm
section)
22 MJ/hr
20 MJ/hr
(20,000 Btu/hr) (18,956 Btu/hr)
Supply Pressure
Burner Operating Pressure
Open Burner
(each)
22 MJ/hr
(20,000 Btu/hr)
Griddle
(each 300mm
section)
20 MJ/hr
(18,956 Btu/hr)
1.13 - 3.40 kPa
(4.5” -13.5” w.c.)
2.75 - 4.50 kPa
(11” -18.0”w.c.)
1.0 kPa (*)
(4.0” w.c.)
2.6 kPa (*)
(10.0” w.c.)
Gas Connection
¾” BSP Male
- UK Only:
Heat Input (net)
Gas Rate (net)
Nominal
Propane
(G31)
Open Burner
Griddle
(each)
(each 300mm
section)
4.6 kW
5.0 kW
Reduced
1.7 kW
1.5 kW
1.5 kW
2.2 kW
Nominal
0.53 m3/hr
0.53 m3/hr
0.36 kg/hr
0.39 kg/hr
m3/hr
m3/hr
0.12 kg/hr
0.17 kg/hr
Reduced
Supply Pressure
Burner Operating Pressure
Gas Connection
Natural Gas
(G20)
Open Burner
Griddle
(each)
(each 300mm
section)
5.0 kW
5.0 kW
0.18
0.16
20 mbar
37 mbar
10 mbar (*)
28 mbar (*)
¾” BSP Male
3