Suspended Furnace Support
FIRE, EXPLOSION,
AND
POISONING HAZARD
CARBON
The furnace may be supported under the entire length of the
furnace with threaded rod and angle iron. (See Figure 24)
Secure angle iron to bottom of furnace as shown.
MONOXIDE
Failure to follow this warning could result in personal
injury, death, or property damage.
Do not install the furnace on its back or hang furnace with
control compartment facing downward. Safety control
operation will be adversely affected. Never connect
return-air ducts to the back of the furnace.
Figure 24
1Suspended
Platform
Furnace
Support
Construct working platform at location where all required
furnace clearances are met. (See Table 1 and Figure 25) For
furnaces with 1-in. (25 mm) clearance requirement on side, set
furnace on non-combustible
blocks, bricks or angle iron. For
crawlspace installations, if the furnace is not suspended from
the floor joists, the ground underneath furnace must be level
and the furnace set on blocks or bricks.
Furnace Installation
--
COMBUSTION
- AIR
(SEE VENTING
SECTION)
PiPE
VENT
NOTE:
EXTEND
ANGLE
IRON OUT FOR
COIL SUPPORT
HEX
NUT
& WASHER
REQD.
PER
(4)
ROD
NOTES:
ROD
LOCATION
USING
DIMPLE
LOCATORS_
1. A 1 In. (25mm) clearance minimum between
top of furnace and combustible material
I
2. The entire length of furnace must be
supported when furnace is used in horizontal
position to ensure proper drainage.
Al1155
3. Furnace
Refer
shown
to the Venting
is a direct
section
vent
application.
for agowable
vent
configurations.