Transcript
DSE Model 5110 Automatic Start Engine Management Instrumentation System 5 PROTECTIONS The module will indicate that an alarm has occurred in several ways; The “Common alarm” LED will illuminate (Warning = Red steady, Shutdown = Red Flashing) If appropriate, the LCD display or LED indicators will display the appropriate alarm icon i.e. for battery charging failure : RPM Hz 51 . 0 1530 If no alarms are present the LCD will extinguish any alarm icons. In the event of a warning alarm the LCD will display the appropriate icon. If a shutdown then occurs the module will display the appropriate icon. The original warning alarm icon will remain displayed. Example:PSI BAR 0.8 11.0 Charge alternator warning (all symbols steady) Followed by…. Hz 0. 0 RPM 0 Charge alternator warning indicator still present, common alarm indicator has changed to a shutdown symbol and is now flashing. Also present is the flashing overspeed LED. Overspeed and Shutdown alarm Icons are displayed flashing. The original warning will remain displayed as long at the triggering conditions remain. Any subsequent warnings or shutdowns that occur will be displayed steady, therefore only the first-up shutdown will appear flashing. Part No. 057-009 5110 Operating Manual Issue 3.3 3/1/2006 11