Download Citizen C70 Specifications
Transcript
I Alarms Network Errors (L) 12. Network Errors (L) L10 DN INIT. ERR. 1 36 (Error-detected module I/O No.) Details A deviceNet initialization error has occurred. The error-detected node No. is FFH. - The value of the local node No. (MAC ID) is out of range. - The value of the mode switch is out of range. "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. Remedy - Set the local node number between 0 and 63. - Set the mode switch to other than D - F. L10 DN INIT. ERR. 1 39 (Error-detected module I/O No.) Details Remedy A deviceNet initialization error has occurred. The error-detected node No. is FFH. - Two or more modes that have the same node No. (MAC ID) exist in the network. "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. - Set non-duplicate node Nos. L10 DN INIT. ERR. 1 E0 (Error-detected module I/O No.) Details Remedy A deviceNet initialization error has occurred. The error-detected node No. is FFH. - Network power is not being supplied. "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. - Supply the network power (24VDC). L10 DN INIT. ERR. 1 E1 (Error-detected module I/O No.) Details Remedy A deviceNet initialization error has occurred. The error-detected node No. is FFH. - Other modules are not found in the network. "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. - Connect other modules in the network. L10 DN INIT. ERR. 1 F0 (Error-detected module I/O No.) Details Remedy A deviceNet initialization error has occurred. The error-detected node No. is FFH. - Node No. setting switch or mode switch setting was changed during operation. "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. - Return the node No. setting switch or mode switch setting to be the original setting. L11 DN INIT. ERR. 2 02 (Error-detected module I/O No.) Details A deviceNet initialization error has occurred. The error-detected node No. is FEH. - The number of input points and output points of the slave node set by parameters are both "0". "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. Remedy - Set the number of input points and output points according to the slave node specifications. L11 DN INIT. ERR. 2 03 (Error-detected module I/O No.) Details Remedy A deviceNet initialization error has occurred. The error-detected node No. is FEH. - The lower byte of the slave node No. in the buffer memory is out of range. "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. - Set it between 0 and 63. L11 DN INIT. ERR. 2 04 (Error-detected module I/O No.) Details Remedy A deviceNet initialization error has occurred. The error-detected node No. is FEH. - The higher byte of the slave node No. in the buffer memory is out of range. "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. - Set it between 01H and 04H, or to 80H. L11 DN INIT. ERR. 2 05 (Error-detected module I/O No.) Details Remedy A deviceNet initialization error has occurred. The error-detected node No. is FEH. - The connection type in the buffer memory is out of range. "Error-detected module I/O No." shows the error-detected module I/O No. with the last digit removed. - Set it to one of the following: 0001H, 0002H, 0004H, or 0008H. I - 65