Download Simrad 38-9 - REV B Installation manual
Transcript
Simrad ES70 Physical and environmental specifications • Connectors: – Transducer: 12-pin female Amphenol, Shell MS3102A-24, Insert 24-19S – AUI: 15-pin female Delta (see below) – Network: 8-pin RJ-45 socket – Auxiliary: 25-pin female Delta • AUI Connector: – Analog input for heave, roll and pitch – Digital trigger in/out – Alarm output – +12 Vdc output (maximum 100 mA) – –12 Vdc output (maximum 100 mA) – +5 Vdc output (maximum 200 mA) • Physical dimensions: – Width: 284 mm – Height: 112 mm – Depth: 246 mm – See also: GPT Outline dimensions on page 102 • Weight: – With one transmitter board: 2.7 kg – With two transmitter boards: 3.3 kg – With three transmitter boards: 4.5 kg • Standard supply power: – AC operation: 95 to 265 Vac, 50-60 Hz, 50-100 W – DC operation: 11 to 15 Vdc, 50-100 W • External power supply for specific configurations: – AC input: 230 Vac, 50–60 Hz – DC output: 13.2 Vdc, 10 A – Physical size (excluding mounting brackets) (WDH): 110 x 190 x 54 mm – See also: GPT Power supply outline dimensions on page 104 • Fuses: – AC fuse: Ø5x20 mm, 2 A slow – DC fuse: Ø5x20 mm, 10 A slow or fast • Operational temperature: 0 to +55°C • Storage temperature: -40 to +70°C • Humidity: 5 to 95% relative non-condensing 110 343522/A