Download Dimplex LA 6 MI User`s guide
Transcript
Section 3: Installation considerations The installation of an air source heat pump should be carried out by a Dimplex Accredited installer. Installation location The heat pump is for outdoor installation only. The following should be verified. Further information is available in the planning manual. Fixing of the heat pump The heat pump should be fixed on two flat, horizontal and solid hard surfaces such as concrete pads that are capable of taking the unit‟s weight and draining the condensate. The fixing should be strong enough to prevent the unit from tipping over if the base becomes unlevel over time. Planning permission has been applied for where necessary. There is adequate clearance for efficient performance as shown in Figure 3 and the discharged air does not recirculate. The unit is positioned to minimise the effects of noise upon the properties occupants and its neighbours. The condensate can easily be drained away. Hydraulic connections can easily be made to the heating system and the DHW cylinder. There is no risk of a flammable gas leak or any outlets vents from any other system. The wiring lengths come within reasonable ranges particularly taking note of the 15m controller cable. The heat pump is adequately fixed to prevent tipping. Suggested dimensions of concrete pads A 152 B 980 C 300 D 356 E 400 F 520 G 400 H 600 Figure 2: Top view of two concrete mounting blocks that allow the condensate to drain away via a gravel soak away. Page 7