Download Maytag W10237808A Specifications

Transcript
Base Grille Water Filtration System
Model P2WG2L/P2RFWG2
Model P2WG2/P2RFWG2
Capacity 200 Gallons (757 Liters)
Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,
Mercury, Benzene, Toxaphene, and O-dichlorobenzene.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances
listed below. The
concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the
permissible
limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
Aesthetic Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
NSF Reduction
Requirements
50% reduction
85% reduction
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Reduction
Requirements
1.909 mg/L
9700000 #/mL
Average
Influent
2.0 mg/L + 10%
At east 1O,OOOpart c es/mL
Influent Challenge
Concentration
0.05 mg/L **
2600 #/mL
Maximum
Effluent
<0.05 mg/L
62000 #/mL
Average
Effluent
Lead: @ pH 6.5
Lead: @ pH 8.5
0.010 mg/L
0.010 mg/L
143.33 ug/L
140 ug/L
0.15 mg/L + 10%
0.15 mg/L _+10%
1.0 ug/L
1.0 ug/L
1.0 ug/L
1.0 ug/L
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
0.002 mg/L
0.002 mg/L
0.0058 mg/L
0.00646 mg/L
0.006 mg/L + 10%
0.006 mg/L_+ 10%
0.3 ug/L
1.4 ug/L
0.0002 mg/L
0.0004 mg/L
0.005 mg/L
0.6 mg/L
0.003 mg/L
0.015 mg/L
1.83333 mg/L
0.016 mg/L
0.015 mg/L _+10%
1.8 mg/L _+10%
0.015 mg/L _+10%
0.5 ug/L
4.8 ug/L
1 ug/L
0.0005 mg/L
0.014 mg/L
0.001 mg/L
>97.4
>97,6
Minimum %
Reduction
>99.3
>99.3
>96.5
76.3
>96.5
99.7
>93.2
>97.4
>99,4
Average %
Reduction
>99.3
99.3
96.5
88.1
>96.5
99.9
>93.2
Toxaphene
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (2O°C to 22°C). Rated service capacity = 200 gallons (757 liters).
•
It is essential that operational,
maintenance,
and filter
•
These contaminants
are not necessarily in your water supply.
replacement
requirements
be carried out for the product to
While testing was performed under standard laboratory
perform as advertised.
conditions,
actual performance
may vary.
•
Use replacement filter P2RFWG2, part #4396841.
2008 suggested
retail price of $39.99 U.S.A./S54.95
Canada.
Prices are subject to change without notice.
Model P2WG2L/P2WG2:
Style 1 - When the filter indicator
reads 10%, order a new filter. When the indicator reads 0%, it is
recommended
that you replace the filter.
Style 2 - When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended
that you replace the filter.
Style 3 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter indicator
reads "REPLACE,"
it is recommended
that you replace the filter.
Style 4 - Press FILTER to check the status of your water filter. If
the filter indicator light is yellow, order a new filter. If the filter
indicator light is red, it is recommended
that you replace the filter.
Change the water filter cartridge every 6 months. If the water
flow to the water dispenser or ice maker decreases noticeably
before 6 months have passed, replace the water filter cartridge
more often.
*Class I particle size: >0.5 um to <1 um
**Test requirement is at least 100,OOO particles/mL
® NSF is a registered trademark
16
of NSF International.
of AC Fine Test Dust.
•
•
The product is for cold water use only.
Do not use with water that is microbiologically
unknown quality without adequate disinfection
system.
•
Refer to the "Warranty"
address and telephone
section for the Manufacturer's
number.
name,
•
Refer to the "Warranty"
warranty.
section
limited
unsafe or of
before or after the
for the Manufacturer's
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33 ° - 100°F (0.6 ° - 37.8°C)
0.85 gpm (3.2 Lpm) @ 60 psi