Testing the E1 Setup Testing the E1 Setup Testing the Installation Use the samples that came with your software to test your boards, devices, and installation before you write your application. You can use the provided source code to help develop your application. The samples are located in subdirectory \RHT\SAMP\E1. The most useful samples are: E1INIT Sets the clock, initializes carrier parameters, and checks carrier status. Older samples set the clock reference as being Trunk A and configured the carrier to disable HDB3 and CRC. If your installation requires different values, make sure to alter the samples accordingly. Newer samples configure most of the parameters using the command line. The defaults are the same as those in the older samples. WAITRING [line] Waits for a call on the specified line (0 by default). OFFHOOK [line] Answers an inbound call or initiates an outbound call. ONHOOK [line] Disconnects a call on the specified line (0 by default). DISLN [line] Disconnects a call on the specified line (0 by default). WAITANS [line] Waits for the remote end to answer on the specified line (0 by default). BLKLN [line] Blocks the line. FRLN [line] Sends a Forced Release signal to terminate the call. WAITOFF [line] Monitors for a disconnect on the specified line (0 by default). WAITIDLE [line] Waits for an idle pattern on the line (0 by default). LSB [line] Displays all relevant information about a line (structure RTNI_lineStatus_s). PLAYE [line] [file] Plays a file while monitoring for a disconnect on the line (default: line 0, file test.vox). August 2001 129