Download Dimplex LA 16 MI Technical data

Transcript
Heat pump for heating purposes – air source – outdoor installation
Special accessories for air-to-water heat pump installed outdoors
Electric connecting line heat pump – heat pump manager
Control line between the heat pump manager and the air-to-water heat pump for outdoor installation. Wired ready for use and with
coded plug connections at both ends for installation in a protective tube (min. diameter 70 mm, non-confusable: Round plug for connection to the heat pump).
EVL ...
Order reference
Art.-Nr.
EVL 996-1
321990
EVL 997-1
322000
EVL 998-1
322010
EVL 999-1
359120
for device type
Length
m
Weight
kg
10
2.9
20
4.6
LA..AS
LA ..PS
LA ..MS
30
8.7
40
12.8
Should be installed separately from the mains cable.
Extension of the control line by the owner is not allowed!
EVL
997-1
998-1
EVL 996-1
999-1
321990
322000
322010
359120
4015627321991
4015627322004
4015627322011
4015627359123
Electric connecting line heat pump – heat pump manager
Control line between the heat pump manager WPM 2006 R and a reversible air-to-water heat pump for outdoor installation. Wired ready
for use und with coded plug connections on both ends (non-confusable) for installation in a protection tube (diameter min. 70 mm).
EVL 10...30R
Order reference
Art.-Nr.
EVL 10R
EVL 20R
EVL 30R
342530
EVL 40R
363720
for device type
Length
m
Weight
kg
342510
10
5
342520
20
9
30
14
40
18
LA...R
Should be installed separately from the mains cable.
Extension of the control line by the owner is not allowed!
EVL
20R
30R
EVL 10R
40R
342510
342520
342530
363720
4015627342514
4015627342521
4015627342538
4015627363724
Heating water connection line, heat pump – heating system
Optimised for connection to a heat pump
Isolated 2-pipe system (suitable for ground-laying) with ready-to-use 90° bend for connection to a heat pump installed outdoors.
Suitable for heat pumps for heating and cooling; max. operating temperature 95 °C; max. operating pressure 6 bar (at 65 °C – 9 bar);
loading capacity SWL 60 (33 kN/m)2). Consisting of PE-Xa medium pipes with EVOH barrier layer to prevent oxygen diffusion, closed-cell
crosslinked PE foam and a highly-flexible corrugated PE-HD cover pipe; includes a ready-to-use 90° connection pipe (length 1.2 m) for
quick and easy connection to the heat pump, including two PE end caps, hazard-warning tape „Caution district heating“ and four screw
fittings (2 x 1¼“ internal thread, 2 x 1¼“ external thread).
Order reference
Art.-Nr.
Connection heating
HVL25-50
358650
Length 5 m + 1.2 m connection pipe,
2 x 32/2.9 Ø cover pipe, 145 mm
29
358660
Length 7.5 m + 1.2 m connection pipe,
2 x 32/2.9 Ø cover pipe, 145 mm
33
HVL25-100
358670
Length 10 m + 1.2 m connection pipe,
2 x 32/2.9 Ø cover pipe, 145 mm
38
HVL25-150
358880
Length 15 m + 1.2 m connection pipe,
2 x 32/2.9 Ø cover pipe, 145 mm
42
358680
Length 15 m + 1.2 m connection pipe,
2 x 40/3.7 Ø cover pipe, 175 mm
61
358690
Length 20 m + 1.2 m connection pipe,
2 x 40/3.7 Ø cover pipe, 175 mm
74
358700
Length 25 m + 1.2 m connection pipe,
2 x 40/3.7 Ø cover pipe, 175 mm
88
HVL25-75
HVL32-150
HVL32-200
HVL32-250
Features
⬙
HVL..
1¼
Weight
kg
Additional, transitional screw connections (1½“ thread-sealing to 1 ½“ flat-sealing) are required for high-efficiency heat pumps.
The pressure drops required for pump dimensioning can be found in the installation instructions.
HVL
25-75
25-100
HVL
25-150
32-150
32-200
HVL25-50
32-250
14
358650
358660
358670
358880
358680
358690
358700
4015627358652
4015627358669
4015627358676
4015627358881
4015627358683
4015627358690
4015627358706
www.dimplex.de/en
2010