Download Dimplex LA 16 MI Technical data
Transcript
Heat pump for heating purposes – air source – outdoor installation Special accessories for air-to-water heat pump installed outdoors Electric connecting line heat pump – heat pump manager Control line between the heat pump manager and the air-to-water heat pump for outdoor installation. Wired ready for use and with coded plug connections at both ends for installation in a protective tube (min. diameter 70 mm, non-confusable: Round plug for connection to the heat pump). EVL ... Order reference Art.-Nr. EVL 996-1 321990 EVL 997-1 322000 EVL 998-1 322010 EVL 999-1 359120 for device type Length m Weight kg 10 2.9 20 4.6 LA..AS LA ..PS LA ..MS 30 8.7 40 12.8 Should be installed separately from the mains cable. Extension of the control line by the owner is not allowed! EVL 997-1 998-1 EVL 996-1 999-1 321990 322000 322010 359120 4015627321991 4015627322004 4015627322011 4015627359123 Electric connecting line heat pump – heat pump manager Control line between the heat pump manager WPM 2006 R and a reversible air-to-water heat pump for outdoor installation. Wired ready for use und with coded plug connections on both ends (non-confusable) for installation in a protection tube (diameter min. 70 mm). EVL 10...30R Order reference Art.-Nr. EVL 10R EVL 20R EVL 30R 342530 EVL 40R 363720 for device type Length m Weight kg 342510 10 5 342520 20 9 30 14 40 18 LA...R Should be installed separately from the mains cable. Extension of the control line by the owner is not allowed! EVL 20R 30R EVL 10R 40R 342510 342520 342530 363720 4015627342514 4015627342521 4015627342538 4015627363724 Heating water connection line, heat pump – heating system Optimised for connection to a heat pump Isolated 2-pipe system (suitable for ground-laying) with ready-to-use 90° bend for connection to a heat pump installed outdoors. Suitable for heat pumps for heating and cooling; max. operating temperature 95 °C; max. operating pressure 6 bar (at 65 °C – 9 bar); loading capacity SWL 60 (33 kN/m)2). Consisting of PE-Xa medium pipes with EVOH barrier layer to prevent oxygen diffusion, closed-cell crosslinked PE foam and a highly-flexible corrugated PE-HD cover pipe; includes a ready-to-use 90° connection pipe (length 1.2 m) for quick and easy connection to the heat pump, including two PE end caps, hazard-warning tape „Caution district heating“ and four screw fittings (2 x 1¼“ internal thread, 2 x 1¼“ external thread). Order reference Art.-Nr. Connection heating HVL25-50 358650 Length 5 m + 1.2 m connection pipe, 2 x 32/2.9 Ø cover pipe, 145 mm 29 358660 Length 7.5 m + 1.2 m connection pipe, 2 x 32/2.9 Ø cover pipe, 145 mm 33 HVL25-100 358670 Length 10 m + 1.2 m connection pipe, 2 x 32/2.9 Ø cover pipe, 145 mm 38 HVL25-150 358880 Length 15 m + 1.2 m connection pipe, 2 x 32/2.9 Ø cover pipe, 145 mm 42 358680 Length 15 m + 1.2 m connection pipe, 2 x 40/3.7 Ø cover pipe, 175 mm 61 358690 Length 20 m + 1.2 m connection pipe, 2 x 40/3.7 Ø cover pipe, 175 mm 74 358700 Length 25 m + 1.2 m connection pipe, 2 x 40/3.7 Ø cover pipe, 175 mm 88 HVL25-75 HVL32-150 HVL32-200 HVL32-250 Features ⬙ HVL.. 1¼ Weight kg Additional, transitional screw connections (1½“ thread-sealing to 1 ½“ flat-sealing) are required for high-efficiency heat pumps. The pressure drops required for pump dimensioning can be found in the installation instructions. HVL 25-75 25-100 HVL 25-150 32-150 32-200 HVL25-50 32-250 14 358650 358660 358670 358880 358680 358690 358700 4015627358652 4015627358669 4015627358676 4015627358881 4015627358683 4015627358690 4015627358706 www.dimplex.de/en 2010