Download APC ACRP501 Technical data
Transcript
Overview The modular, row-based computer room cooling system offers efficient, predictable, and economical cooling for a variety of spaces. Configuration Critical environmental requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applications, referred to as technology rooms. Critical environment applications include: Compliance Approval • Chilled Water • Air-cooled Air-cooled Standard Features • Insulated cabinet • Backward inclined impeller • Variable speed fans (2) • UL Listed • Shutdown input/alarm output • VDE • Humidifier • CE • Cross circuited cooling coil • C-tick • Electric reheat • C-UL Listed • Pleated 100 mm (4 in) filter • Pipe adapters • Computer rooms • Top or bottom piping • Telecommunication facilities • Clean rooms • Condensate management with dual position float • Power equipment • Network management card • Medical equipment rooms • LAN/WAN environments A worldwide network of APC representatives is fully qualified to provide engineering, sales, installation, and service for our products. APC warrants all parts for 18 months from shipment and 12 months from startup. Extended warranties are available. Capacity The InRow RP chilled water configuration is available in one size with a capacity that is up to 60 kW based on the particular application of the unit. The InRow RP air-cooled configuration is available in one size with a capacity that is up to 37 kW. Chilled Water Standard Features • Insulated cabinet • Backward inclined impeller • Variable speed fans (3) • Shutdown input/alarm output • Chilled water flow meter • Baying kit InRow RP to NetShelter® SX rack • Remote temperature sensor (3) • Microprocessor controller • Variable speed reciprocating compressor using VFD control • Liquid line solenoid valve • Pressure equalization solenoid • 2-way/3-way floating point valve • Humidifier Accessories • Counter flow cooling coil • Cable leak detector • Electric reheat • Baying kit InRow RP to NetShelter VX rack • Pleated 100 mm (4 in) filter • NPT to BSPT pipe adapters • Top or bottom piping • NetShelter SX 42U to 48U height adapters • Condensate management with dual position float • NetShelter VX 42U height adapters • Network management card • Data cable bridge partition • Baying Kit InRow RP to NetShelter® SX rack • Flex hose piping kits • Bridge trough power cable shield • Remote temperature sensor (3) Room Air Distribution • Microprocessor controller Row-based systems are placed in line with rack enclosures. At least one system is used per hot aisle. Air is drawn in through the rear of the system, cooled, and discharged into the cold aisle, thereby neutralizing the sensible heating effects of the data processing equipment.The InRow RP delivers high volumes of airflow to eliminate hot spots in densely populated environments. • Automatic transfer switch InRow RP Technical Data Manual 1