Download DSP TP400 PC Technical information
Transcript
VLT® HVAC Drive Programming Guide Parameter Description 3.16.6 16-9* Diagnosis Read-Outs 16-96 Maintenance Word Range: 16-90 Alarm Word Range: 0* Function: [0 - 4294967295 ] View the alarm word sent via the serial communication port in hex code. 16-91 Alarm Word 2 Range: 0* Function: [0 - 4294967295 ] View the alarm word 2 sent via the serial communication port in hex code. 16-92 Warning Word Range: 0* Bit 10: Drive cooling fan Bit 11: Drive system health check [0 - 4294967295 ] View the warning word sent via the serial communication port in hex code. Bit 13: Maintenance Text 0 Bit 14: Maintenance Text 1 Bit 15: Maintenance Text 2 Bit 16: Maintenance Text 3 Bit 17: Maintenance Text 4 Positio n3⇒ Positio n2⇒ 16-94 Ext. Status Word Range: 0* Valve Fan Pump Motor bearing bearing bearing s s s Pump seals Temper Flow Pressur ature transmi e transmi tter transmi tter tter Function: [0 - 4294967295 ] View the warning word 2 sent via the serial communication port in hex code. Drive Drive system cooling health fan check Filter Positio Function: [0 - 4294967295 ] Returns the extended status word sent via the serial communication port in hex code. 3 3 Bit 12: Warranty n 4⇒ 16-93 Warning Word 2 0* • • • • • • • • Positio Function: Range: Function: Fan belt Warrant y n 1⇒ 0hex - - - - 1hex - - - + 2hex - - + - 16-95 Ext. Status Word 2 3hex - - + + Range: 4hex - + - - 5hex - + - + 6hex - + + - 7hex - + + + 8hex + - - + 0* Function: [0 - 4294967295 ] Returns the extended warning word 2 sent via the serial communication port in hex code. 16-96 Maintenance Word 9hex + - - Range: Ahex + - + - Bhex + - + + Chex + + - + 0 * [0 4294967295 ] Function: Readout of the Preventive Maintenance Word. The bits reflect the status for the programmed Preventive Maintenance Events in parameter group 23-1*. 13 bits represent combinations of all the possible items: • • • • • • • • • • Dhex + + - Ehex + + + - Fhex + + + + Bit 0: Motor bearings Bit 1: Pump bearings Bit 2: Fan bearings Bit 3: Valve Bit 4: Pressure transmitter Example: The Preventive Maintenance Word shows 040Ahex. Position 1 2 3 4 hex-value 0 4 0 A Bit 5: Flow transmitter Bit 6: Temperature transmitter Bit 7: Pump seals Bit 8: Fan belt Bit 9: Filter MG11CD02 - VLT® is a registered Danfoss trademark The first digit 0 indicates that no items from the fourth row requires maintenance The second digit 4 refers to the third row indicating that the Drive Cooling Fan requires maintenance 125