Download SATO DR308e Technical data
Transcript
Unit 4: Standard Command Codes BAR CODES OUPUT Without Incrementing: <ESC>A<EXC>H0100<EXC>V0100 <ESC>BI104150101234567000000001 <ESC>Q2<ESC>Z (4-22a) With Incrementing: <ESC>A<ESC>H0100<ESC>V0100 <ESC>F001+001<ESC>BI104150101234567000000001 <ESC>Q2<ESC>Z (4-22b) NOTES UPC and EAN bar codes are not affected by the different types of narrow to wide ratios. Instead, the <ESC>D command adds descender bars to these codes where needed to meet UPC specifications. The <ESC>BD command puts desender bars and human readable text below the symbol. The Code 128, UCC 128, MSI, and Code 93 bar codes are not affected by the narrow to wide ratios. The Codabar, Code 39, Industrial 2 of 5, and Matrix 2 of 5 bar codes are affected by the Character Pitch command. This command must be placed before the Bar Code command. Because of their unique characteristics, two-dimensional (2D) symbols are covered separately. For UCC128, the FNC1 code is automatically inserted and the Mod 10 and Mod 103 check digits are automatically calculated. For the MSI bar code, the check digit is not automatically calculated. The <ESC>D and <ESC>BD commands are not valid for the MSI, Code 128, Code 93, UPC-E, Bookland, UCC128 and Postnet symbologies. Refer to Appendix: Reference Tables 24 through 26 for additional information. SATO GL4xxe SBPL Programming Reference Page 4-31