Download Dometic RM 2553 Technical data
Transcript
Dometic® MANUAL Refrigerators SYMPTOM CAUSE REFER TO SECTION PAGE 8. Insufficient cooling on AC. Cools properly on DC and gas. AC Volts Heating Element 2F 3F 65 65 9. Insufficient cooling on DC. Cools properly on AC and gas. DC Volts Heating Element Wiring 4F 3F B 65 65 18,19,21 10. Insufficient cooling on gas. Cools properly on AC and DC. LP gas Orifice Flue Baffle Flue Tube Flue Cap Burner 1A 3A 2A,3A 3A 3A 2A 12 14 12,13 14 14 12 11. Freezes on all modes. Thermostat DC Volts 5F 4F 65 65 12. Changes preset mode. DC Volts Wiring Circuit Board 4F B 5F 65 18,19,21 70,71 13. Flame failure light within 10 seconds. Igniter High Voltage Cable Electrode Wiring 5F 5F 5F B 66 66 66 18,19,21 14. Flame failure light after 3 minutes. LP Gas Manual Gas Valve Solenoid Orifice Burner Wiring Thermocouple 1A 2A 5F 3A 2A,3A B 5F 12 12 65,66 14 12 18,19,21 66 15. Interior Light ON when door is closed. Wiring Door Switch Door Position B 5F 4J 18,19,21 67 90 16. Rapid formation of frost. Food Storage Interior Liner Seal to Frame High Humidity Air Leaks 7J 9J 8J 3J 90 90 90 89 4