Download Elta LE100 Specifications

Transcript
Tables 5.14 and 5.15 list the levels shown in Figures 5.20 and 5.21 respectively.
Table 5.14 VA and VDD5 Power Supply Output Noise Limits for C-band
Frequency (kHz)
VA Noise Level
w/3kHz filter
(dBV)
VDD5 Noise Level
w/3kHz filter
(dBV)
10-40
-20
-40
40-55
-20
-50
55-110
-30
-50
110-115
-40
-50
115-135
-40
-70
135-1000
-40
-50
Frequency
(kHz)
VDD5 Noise Level
w/300Hz filter
(dBμV)
110-138
-60
Table 5.15 VA and VDD5 Power Supply Output Noise Limits for A-band
Frequency (kHz)
VA Noise Level
w/3kHz filter
(dBV)
VDD5 Noise Level
w/3kHz filter
(dBV)
10-55
-20
-40
55-75
-35
-40
75-85
-40
-70
85-110
-35
-45
110-200
-40
-45
200-1000
-40
-40
Frequency (kHz)
VDD5 Noise Level
w/300Hz filter
(dBμV)
70-90
-60
PL 3120/PL 3150/PL 3170 Power Line Smart Transceiver Data Book