6. Commands description
6.1.
Escape commands for the contact interface
6.1.1. Sending escape commands to @MAXX lite
A developer can use the following method to send escape commands to @MAXX lite for the
contact interface
•
SCardControl method defined in PC/SC API
6.1.2. Escape command codes
Escape commands can be used by an application to configure @MAXX lite to function in a
mode that is not its default configured mode or to get specific information. To put the @MAXX
lite back into its default mode, either the @MAXX lite has to be unplugged and plugged again
or the application can send again the same escape command.
The following escape commands are supported by @MAXX lite for the contact interface
S.No.
Escape message ID
Value
1
CCID_ESC_GETINFO
0x00
2
CCID_ESC_SETMODE
0x01
3
CCID_ESC_GETMODE
0x02
4
CCID_ESC_GET_FW_VERSION
0x03
5
CCID_ESC_SET_POWER_ON_RESET_ORDER
0x04
6
CCID_ESC_EMV_LOOPBACK
0x05
7
CCID_ESC_APDU_TRANSFER
0x08
8
CCID_ESC_CLK_FREQUENCY
0x1F
9
CCID_ESC_GET_SET_ETU
0x80
10
CCID_ESC_GET_SET_WAITTIME
0x81
11
CCID_ESC_GET_SET_GUARDTIME
0x82
12
CCID_ESC_GET_SET_EGT
0x83
13
CCID_ESC_GET_SET_ATR_TIMEOUT
0x84
14
CCID_ESC_POWER
0xC0
15
CCID_ESC_ROUGH_TANSFER
0xC1
16
CCID_ESC_GET_SET_PROTOCOL
0xC2
17
CCID_ESC_GET_SET_TA1_RFU
0xC3