Download Bosch 16P Specifications
Transcript
1.2 Technical specifications 1.2.1 Electronic gas hot water systems Highflow range Models Part number 50°C limited (MP52)* Ignition type Flow rate L/min (25°C rise) Flow rate L/min (50°C rise) Mj/h Star rating Antifrost Installation Air supply / exhaust Gas type Gas supply pressure (kPa) Min. inlet water pressure for max. flow (kPa) Max. allowable inlet water pressure (kPa) Min flow rate (L/min) Electricity *50°C limited Highflow models only available in Australia. These units comply with Australian Standards 3489-2003 (licence number IPC20002). They have been specifically designed for applications, which require a maximum water temperature of 50°C. This eliminates the need for mechanical tempering valves. **Only available in Australia. ***Only available in New Zealand. 50°c This appliance delivers water NOT EXCEEDING 50°C in accordance with AS3498. Refer to AS/NZ3500, local requirements and installation instructions to determine if additional delivery temperature control is required. Highflow 17e YS1770RA YS1770RA5* Electronic 17 8.5 135 5.66 Standard External Power Flued NG/LPG NG: 1.13 – 3.0 LPG: 2.75 – 3.0 Highflow 21e YS2170RA YS2170RA5* Electronic 21 10.5 170 5.56 Standard External Power Flued NG/LPG NG: 1.13 – 3.0 LPG: 2.75 – 3.0 Highflow 26e YS2670RA YS2670RA5* Electronic 26 13 200 5.53 Standard External Power Flued NG/LPG NG: 1.13 – 3.0 LPG: 2.75 – 3.0 100 130 230 1,000 1,000 1,000 2.5 2.5 2.5 Supply (VAC) 230 - 240, 50 Hz (10 amp weatherproof power point recommended within 500 mm of the unit) Power Consumption (watts) In use: 40 Antifrost: 129 In use: 45 Antifrost: 129 In use: 51 Antifrost: 129 20 20 20 20 20 20 20 20 20 20 20 20 Pipe Connection Sizes Gas NG (mm) Gas LP (mm) Cold Water (mm) Hot Water (mm) Unit Dimensions Height (mm) Width (mm) Depth (mm) Carton weight (in kg) Domestic Warranty Parts and labour Heat exchanger Temperature controllers Optional Temperature Controllers Main controller Bathroom controller Sub-controller Accessories Lockable recess box Fully enclosed recess box Pipe cover (3/4”) (3/4”) (3/4”) (3/4”) 520 350 170 18 (3/4”) (3/4”) (3/4”) (3/4”) 520 350 170 19 (3/4”) (3/4”) (3/4”) (3/4”) 600 350 170 22 3 years 10 years (part only) 3 years (parts and labour) Standard: YPRM66XB**; Premium: YPRM67XB Standard: YPRS66XB**; Premium: YPRS67XB YPRP62XB 17 and 21e: RBHF50L**, 26e: RBHF26L** FERB70**, RBHF304WDA*** YPHC304 5