Download Basler A102f User`s manual
Transcript
DRAFT Configuring the Camera 4-14 Register Name: Trigger Inquiry Offset from Base Address: 0x530 Field Bit Description A102f Value A102fc Value Presence Inq 0 Trigger control feature is present 1 1 Abs Control Inq 1 Trigger can be set with an absolute value 0 0 --- 2 ... 3 Reserved --- --- Read Out Inq 4 The trigger value can be read 1 1 On/Off Inq 5 Trigger control can be switched on/off 1 1 Polarity Inq 6 The trigger input polarity can be changed 1 1 Value Read 7 The raw trigger input can be read 1 1 Trigger Source 0 Inq 8 Trigger source 0 is present (ID = 0) 1 1 Trigger Source 1 Inq 9 Trigger source 1 is present (ID = 1) 1 1 Trigger Source 2 Inq 10 Trigger source 2 is present (ID = 2) 1 1 Trigger Source 3 Inq 11 Trigger source 3 is present (ID = 3) 1 1 --- 12 ... 14 Reserved --- --- Software Trigger Inq 15 Software trigger is present (ID = 7) 1 1 Trigger Mode 0 Inq 16 Trigger mode 0 is present 1 1 Trigger Mode 1 Inq 17 Trigger mode 1 is present 1 1 Trigger Mode 2 Inq 18 Trigger mode 2 is present 0 0 Trigger Mode 3 Inq 19 Trigger mode 3 is present 0 0 Trigger Mode 4 Inq 20 Trigger mode 4 is present 0 0 Trigger Mode 5 Inq 21 Trigger mode 5 is present 0 0 --- 22 ... 29 Reserved --- --- Trigger Mode 14 Inq 30 Trigger mode 14 is present (Vendor unique trigger mode 0) 0 0 Trigger Mode 15 Inq 31 Trigger mode 15 is present (Vendor unique trigger mode 1) 0 0 BASLER A102f