SLM-5650 Satellite Modem Remote Control Command (Instruction Code and Qualifier) Arguments for Command or Response to Query Tx Carrier State TXO= 1 byte, value of 0 thru 3 Rx Frequency RFQ= 9 bytes Parameter Type Revision 1 MN/SLM5650.IOM Description of Arguments Command or Query. Tx Carrier State, where: 0=OFF due to front panel or remote control command 1=ON 2=RTS 3=OFF due to ext H/W Tx Carrier Off command (not a valid argument when used as a command) Example: TXO=1 (Tx Carrier ON) Command or Query. Rx Frequency, 52 to 88 MHz, 104 to 176 MHz, and 950 MHz to 2000 MHz. Resolution=100Hz. Response to Command Query (Instruction Code and Qualifier) Response to Query TXO= TXO? TXO* TXO# TXO? TXO=x (see description of arguments) RFQ= RFQ? RFQ* RFQ# RFQ? RFQ=xxxx.xxxx (see description of arguments) RFM= RFM? RFM* RFM# RFM? RFM=x (see description of arguments) RFT= RFT? RFT* RFT# RFT? RFT=x (same format as command argument) Example: RFQ=0140.9872 Rx Framing Mode RFM= 1 byte, value of 0 thru 2, 4 Command or Query. Rx Overhead Type, where: 0=None (Unframed) 1=IBS 2=IDR 4=AUPC Depending on Modem mode, not all of these selections will be valid. Rx FEC Type RFT= 1 byte, value of 0 thru 2 Example: RFM=0 (selects Unframed mode) Command or Query. Rx FEC coding type, where: 0=None (Uncoded) 1=Viterbi 2=Turbo Example: RFT=2 (which is Turbo coding) B–14