7.7.2.4 Menu structure and
parameters
DEMAG D-SH
Ver.: x.yz
The diagram below shows the menu tree and the available parameters and diagnosis variables.
Diagnosis
Inputs/outputs
• I Lifting
• I Lowering
• I Emergency stop
• I Lifting motion limit switch
• I Lowering motion limit switch
• O Digital output
• O Brake release
Measured values
• Setpoint speed value
• Actual speed value
• DC link voltage
• Inverter temperature
• Incremental analogue value
• Position
• Counter value
System status
• Current Error
• Error memory
• Lifting disabled
• Lowering disabled
• Motor overtemp.
• Inverter overtemp.
• SW vers. inverter
Operating data
Operating parameters
• Operating hours
• Type of hoist
• Maximum speed
• Minimum speed
• Accelerating time
• Braking time
• Fast-to-slow switch active
• Position fast-to-slow switch top
• Position fast-to-slow switch bottom
• Digital output assignment
• Factor speed lowering
Functions
Setup
• Control of PLC
• Reset, load default values
• Language selection
• Password entry
7.7.2.5 Setup
70
Parameter name
Remark
Language selection
Here you may choose between German and English. To do this, change to edit mode and select the
required language.
Password entry
Further functions can be enabled here by entering a password.
21115144_en_310310
Control switches
© Demag Cranes & Components GmbH
Device parameters