FLUE DRAFT CONTROL OPERATION
The purpose of the Flue Draft Control (Fig. 6) is to prevent flames from coming out of the fire door toward the operator. The draft control lever is designed in such a way so that the upper door may not be
opened without opening the rear damper and allowing the draft to go up the chimney.
WARNING - NEVER OPEN EITHER DOOR WHEN THE BOILER IS IN OPERATION WITHOUT OPENING THE FLUE DRAFT CONTROL.
TO LOAD OR RELOAD THE BOILER FIREBOX,
ALWAYS FOLLOW THIS PROCEDURE:
1)
OPEN FLUE GATE BY PUSHING DRAFT CONTROL LEVER AS FAR TO THE REAR AS IT WILL
GO (Fig.8).
2)
TURN OFF DRAFT FAN AT CONTROL PANEL.
3)
OPEN DOOR AND LOAD FUEL.
4)
CLOSE AND LATCH DOOR.
5)
PULL DRAFT CONTROL LEVER ALL THE WAY
FORWARD (Fig.9).
6)
TURN DRAFT FAN ON ONCE AGAIN.