Download 5-0171 - Concorde Battery

Transcript
1502
1503
1504
1505
LP-1
Revised 7.B to include OCV criteria: If the OCV is 20 volts or above (10
volts for a 12 volt battery), charge the battery at constant potential per
Section 8. If the OCV is below 20 volts (10 volts for a 12 volt battery),
perform the deep discharge recovery charge per Section 9. Revised 7.E to
include recording discharge minutes and % capacity on Battery
Maintenance Log. Reworded 7.G.
Revised Section 8, Conditioning Charge Procedure, to one method only (16
hour constant current at C/10 rate).
Added new Section 9, Deep Discharge Recovery Procedure.
Revised 10.C to include IMDG and DOT regulations.
Added Appendix A, Battery Maintenance Log
24-30-71
All Models
All Models
All Models
All Models
All Models
Highlights
Page 2 of 2
Mar 31/2015