IX. Wiring Diagrams/Tech Sheet Measuring SHU995X, SHV68 Resistances @ Modules Control Module -- I2 Measure rinse agent sensor (~ .4 Ω) Measure Top Rack Only actuator (SHV 68 only) (~ .4 Ω) Measure dispenser actuator (~ 2150 Ω) Measure NTC (~ 55 kΩ @ 72ºF) To Aqua Sensor To heater, Hi-Limit & flow switch Wire color codes: BK = Black BN = Brown BU = Blue GY = Gray RD = Red WH = White YE = Yellow HINT: To measure integrated model resistances while door is open, use a screwdriver to trip door latch closed. Measure Circulation Motor (with door closed) (~ 10 Ω) NOTE: Can also measure between VT wire on terminal # 2 on e1 door switch and GY wire on module terminal I2.7-1 HINT: Water valve and drain motor can be measured from front of dishwasher without accessing control module wire harnesses. Resistances are: ν Water valve ~ 1 k ν Drain motor ~ 16.5 102