Download DURKOPP ADLER 511 - Operating instructions
Transcript
Output test With this testing function, the function of the output elements is checked. – – Start testing function with the “OK” key. Select the desired output element by pressing the “ñ” or “ò” keys. – Switch the selected output element on and off by pressing the “OK” key. ==== Output test ==== Output Y1: + – Press the function key “ESC” in order to leave the testing function. Caution – Risk of Injury ! Do not reach into the running machine during the function test of the output elements. Outputelement Function Y1 Thread clamp/thread wiper (option) Y2 Magnetic valve for the pneumatic sewing foot lift Y4 Thread tension Y13 Thread trimmer magnet Y18 Separated clamping foot 1, if the option is activated Y19 Separated clamping foot 2, if the option is activated Y21 Laser marking light 1, if the option is activated Y22 Laser marking light 2, if the option is activated Y23 Laser marking light 3, if the option is activated Also refer to the “Distributor PCB” section The current configuration of the outputs is indicated in the sub-menu “Output assignments” in the “Configuration” menu. 51 1