Download Vaillant ECOmax VUW 286 E Technical data
Transcript
fig. 87 GW 472/0 7.17.1 Replacement of diverter valve diaphragm (fig. 87). Remove diverter valve as in Section • 7.17 • Remove the 4 screws (1). • Lift top off diverter valve and remove diaphragm. • Replace in reverse order. • Carry out electrical checks (see Section 5.1). • Refill and repressurise the boiler (see Section 5.4). 7.18 Replacement of pressure gauge (fig. 88) • • • • • drain boiler as in Section 7.1.2. Remove front casing as in Section 7.1.3. Lower front control panel as in Section 7.1.6. Undo union (1) at rear of pressure gauge, depress side springs on pressure gauge with a screwdriver and pull forward to remove. Replace in reverse order. Refill and repressurise the boiler (see Section 5.4). fig. 88 GW 473/0 • Turn off boiler as in Section 7.1.1. • Release CH water pressure and 7.19 Replacement of water section • • • • supply. Turn off mains water isolating valve and open a hot tap. Remove front casing as in Section 7.1.3. Lower front control panel as in Section 7.1.6. Undo union (1, fig. 89) remove spring clip (1, fig. 90) by lifting, pull pipe (2, fig. 90) forward and remove. fig. 89 GW 458/0 • Isolate boiler from the mains 51