Download Encore SIM EDITOR SOFTWARE User guide
Transcript
PLI Specifications The valid PLI specifications are as follows: call=function Specifies the name of call function. This specification is required. check=function Specifies the name of check function. misc=function Specifies the name of misc function. data=integer Specifies the data value passed as first argument to call, check, and misc routines. The default is 0. Use this argument if you want more than one user-defined system task or system function to use the same call, check, or misc function. Specify a different integer for each user-defined system task or system function in the PLI table file that uses the same call, check, or misc function. size=number Specifies the size of returned value in bits. This specification is required for user-defined system functions. You can omit this specification or specify 0 in the PLI specifications for a user-defined system function. For user-defined system functions, specify a decimal value for the number or bits. For example: size=64. If the user-defined system function returns a real value, specify r. For example: size=r args=number Specifies the number of arguments to the user-defined system task or system function. minargs=number Specifies the minimum number or arguments. Using the PLI 17-9