Download Comtech EF Data CDD-880 Product specifications

Transcript
CDD-880 Multi Receiver Router
Ethernet-based Remote Product Management
5.4.4.3.3
Revision 1
MN-CDD880
Configuration | ACM
Use this page to configure CDD‐880 ACM (Adaptive Coding Modulation) operations. Figure 5‐12. Configuration | ACM page ACM Demodulator Settings
For each operating demodulator, note the following selections on a per‐column basis from left to right: • Demod # – This is the available "FILLED" demodulator slot (automatically assigned in pairs per each installed dual demodulator card). • ACM Enable – Click to option button to enable or disable ACM operation. • Remote CDM‐840 IP Address – Enter the CDM‐840 Remote Router IP Address in the form XXX.XXX.XXX.XXX. Click [Submit] to save. 5–23