Download Drolet ALASKA 2000 Technical data
Transcript
TABLE OF CONTENT TECHNICAL DATA ......................................................................................................................................... 1 INSTALLATION INSTRUCTIONS .................................................................................................................. 2 Locating the stove ........................................................................................................................................2 Chimney informations...................................................................................................................................3 Connecting the stove to the chimney ...........................................................................................................4 Leveling the unit ...........................................................................................................................................5 Fixation of stove to floor ...............................................................................................................................5 Connecting stove to oil tank .........................................................................................................................6 Adjusting the draught ...................................................................................................................................7 Draught regulator .........................................................................................................................................7 OPERATION INSTRUCTIONS ....................................................................................................................... 8 Combustible .................................................................................................................................................8 Lighting.........................................................................................................................................................8 Changing intensity........................................................................................................................................9 Turning the stove off...................................................................................................................................10 Maintenance...............................................................................................................................................10 Troubleshooting guide................................................................................................................................11 SPARE PARTS ............................................................................................................................................. 13 W A R R A N T Y........................................................................................................................................... 15 TECHNICAL DATA HIMALAYA OIL BURNING STOVE COMBUSTIBLE : HEAT INPUT : Minimum : Maximum : FLOWRATE : Minimum : maximum : MINIMUM DRAUGHT REQUIRED : EFFICIENCY : with fan : without fan : OIL NO 1 kW BTU/h 4,8 16 600 10,7 36 800 cc/min litres/h 9,9 0,59 17,3 1,04 0,05 INWC % 81,5 76,5 CLEARANCES TO COMBUSTIBLES Back Side Corners Top Mm 150 150 150 915 OIL NO 2 kW BTU/h 3,7 12 800 10,3 35 550 cc/min litres/h 8,5 0,35 16,1 0,97 0,05 INWC % 76 73 DIMENSIONS in 6 6 6 36 Height : Width : Depth : Ø outlet flue pipe : Ø burner : A MINIMUM CLEARANCE OF 9’’ FROM PIPE TO COMBUSTIBLES SHOULD BE ALLOWED. Glass ( 3 ) : Weight : Page 1 of 15 mm 800 635 485 130 255 in 31 ½ 25 19 1/8 5 10 460 x 280 80kg 18 x 11 175 lbs