"UniVert 2" inverter 8 Technical Data 8.1 General Data INV DC input current ............................ < rated input current DC fuse required ........................... gL 80 A with type 3.3 kVA 48 V gL 63 A with type 3.3 kVA 60 V gL 20 A with type 3.3 kVA 220 V gL 80 A with type 1.5 kVA 24 V gL 36 A with type 1.5 kVA 48 V gL 32 A with type 1.5 kVA 60 V gL 25 A with type 2.5 kVA 110 V Manufacturing and type test .......... In acc. with DIN 60146 Part 1-1 Emitted interference in acc. with EN 50081-1 - Conducted interference .............. In acc. with EN 55022 Class "B" - Emission...................................... In acc. with EN 55022 Class "B" Noise immunity in acc. with EN 50082-2 - Housing ....................................... ESD test to EN 61000-4-2, 6 kV contact HF field to EN 61000-4-3, 10 V/m (30 MHz – 1 GHz) - Power cables ............................... Burst test in acc. with EN 61000-4-4, 2 kV Surge test in acc. with EN 61000-4-5, 2 kV asymmetrical - Control cables ............................. Burst test in acc. with EN 61000-4-4, 2 kV Surge test in acc. with EN 61000-4-5, 2 kV asymmetrical Functional extra-low voltage .......... With safe isolation at UO ≤ 60 V DC to VDE 0100 Part 410 11.83 Section 4.3.2 Dynamic response......................... ≤ 3% with sudden load fluctuations between 0%-100%-0% rated output current Overload behaviour ....................... 1.6 x rated current for 1 minute 1.3 x rated current for 10 minutes Short-circuiting............................... Continued short-circuit-proof Page 31 of 42 8000012364 BAL, en