INSTALLATION AND OPERATING INSTRUCTIONS UNIVERSAL VENT-FREE FIREBOX 36" x 24", 36" x 28" & 42" x 28" Universal Vent-Free Fireboxes P/N 700,032M REV. B 05/2006 MODELS UVF-36 UVFRC-3628 UVFRC-3628-H UVFRC-4228 Shown INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. UVFRC-4228 UVFRC-4228-H FOR USE ONLY WITH A LISTED GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H. In the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter; • See Table of Contents for location of additional Commonwealth of Massachusetts requirements. WARNING: DO NOT ATTEMPT TO BURN SOLID WOOD FUELS, OTHER GAS LOG SETS OR ANY OTHER COMBUSTIBLE MATERIALS IN THIS VENT-FREE FIREBOX. FOR YOUR SAFETY: Do not store or use gasoline or other flammables or liquids in the vicinity of this or any other appliance. FOR YOUR SAFETY: What to do if you smell gas: • DO NOT light any appliance. • DO NOT touch any electrical switches. • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow your gas suppliers instructions. • If your gas supplier cannot be reached, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. OTL Report No.116-F-38-5 DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES. WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH THE DECORATIVE TYPE VENT-FREE ROOM HEATER FOR THE MINIMUM FIREPLACE SIZE REQUIREMENT. DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATIONS. THIS IS A VENT-FREE GAS-FIRED HEATER ENCLOSURE. IT USES AIR (OXYGEN) FROM THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED. REFER TO COMBUSTION AND VENTILATION AIR SECTION, PAGES 3 & 4. Due to high temperatures, the appliance should be located out of traffic and away from furniture or draperies. Do not place clothing or other materials on or near this appliance. IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING YOUR VENT-FREE ROOM HEATERS. IMPORTANT SAFETY INFORMATION INSTALLER: PLEASE LEAVE THESE INSTRUCTIONS WITH THE OWNER. OWNER: PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING If the information in this manual is not follwed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. IMPORTANT The fireplace screens on the appliance must be closed prior to operating the fireplace. WARNING These built-in vent-free fireboxes have only been tested and approved for use with ANSI Z21.11.2 Ventfree gas logs. WARNING Do not attempt to burn solid wood fuels, other gas log sets or any other combustible materials in this vent-free firebox. WARNING Any change to this Vent-Free room heater can be dangerous. Improper installation or use of this heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning. WARNING Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. 2 WARNING Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the Vent-Free Gas Heater serviced as it may not be operating correctly. WARNINGS • Due to high temperatures, the firebox should be located out of traffic and away from furniture and draperies. • Do not place clothing or other flammable material on or near the heater. • Any safety screen or guard removed for servicing the firebox must be replaced and/or closed prior to operating the heater. • Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is important that control compartments, burners and circulating air passageways of the heater be kept clean. • Allow the heater to cool before servicing. Always shut off any electricity or gas to the heater while performing service work. • Do not install the firebox in a sleeping room or bathroom. • The appliance and its individual shut-off valve must be disconnected from the gas supply piping system while performing any tests of the gas supply piping system at test pressures equal to or less than 1/2 psig. NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. WARNING • The heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. • Keep heater area clear and free from combustible materials, gasoline and other flammable vapors and liquids. • Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. • Ensure that the heater is clean when operating. Excessive dust accumulation on the burner and logs will increase the amount of carbon monoxide formation and could lead to carbon monoxide poisoning and death. IMPORTANT Before starting your firebox installation, read these installation instructions carefully to be sure you understand them completely and in entirety. Failure to follow these instructions could cause a heater malfunction resulting in serious injury and/or property damage. WARNING Do not install in the vicinity where gasoline or other flammable liquids may be stored. The Vent-Free firebox must be kept clear and free from these combustible materials. WARNING Maintain minimum clearances. CONGRATULATIONS! Misc. Codes / Standards - In selecting this SUPERIOR Vent-Free Gas Firebox you have chosen the finest and most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fireplace. Welcome to a family of tens of thousands of satisfied SUPERIOR Fireplace Owners. The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your SUPERIOR product. GENERAL INFORMATION TABLE OF CONTENTS Important Safety Information ........... Page Packaging List.................................. Page General Information ......................... Page Burn-in Period.................................. Page Tools/Building Supplies.................... Page Codes ............................................... Page Combustion And Ventilation Air ....... Page Cold Climate Insulation .................... Page New York City Approval.................... Page Requirements for the Commonwealth of Massachusetts Page Location Of Firebox .......................... Page Clearances ....................................... Page Assembly Steps ............................... Page Gas Line Installation......................... Page Firebox Framing ............................... Page Firebox Installation ........................... Page Specifications................................... Page Framing Specifications ..................... Page Canopy Installation .......................... Page Optional Equipment / Blower Kit Installation .................................. Page Firebox Finishes ............................... Page Accessories/components ................. Page Replacement Parts List .................... Page 2 3 3 3 3 3 3 4 4 These Vent-Free firebox enclosures are designed to accept all ANSI Z21.11.2 approved Decorative Type Vent-Free Gas Log Room Heaters. For the appropriate Vent-Free Gas Log Room Heater model, refer to Page 16 (see Vent-Free Gas Log Sets). Refer to the installation instructions provided with the log sets for detailed instructions. 5 6 6 8 8 9 9 10 11 11 This installation manual will enable you to obtain a safe, efficient and dependable installation of your room heater system. 12 15 15 17 This installation manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system. PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE BEGINNING YOUR INSTALLATION. Packaging List Vent-Free Gas Firebox Canopy (optional for models UVFRC-3628, UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H) Installation and Operating Instructions Warranty Certificate Do not alter or modify the firebox or its components under any circumstances. Any modification or alteration of the firebox system, including but not limited to the firebox and accessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation. These Built-In Vent-Free Fireboxes have been tested and approved as Ventless Firebox Enclosures for Gas-Fired Unvented Decorative Room Heaters to ANSI Z21.91. Burn-in Period During the first few times of operation of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. We recommend that you open windows and ventilate the house during the initial burns. The paint emits non-toxic odors during this process. Depending on your use, the burn-in period may take a few hours or a few days. KEEP YOUR HOUSE WELL VENTILATED DURING THE BURN-IN PERIOD. THE ODOR AND HAZE EMITTED DURING THE BURN-IN PERIOD CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. If an optional blower is installed, Do not turn it on during the Burn-In period. NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition. Check the packaging list to be sure that you have all the necessary parts in usable condition. Also check for concealed damage. Tools and Building Supplies Normally Required Tools Should Include: • Phillips screwdriver • Hammer • Saw and/or sabersaw • Level • Measuring tape • Electric drill and bits • Pliers • Square • Piping complying with local codes • Pipe wrench • Tee joint • Pipe compound Building Supplies Should Include: • Framing materials • Wall finishing materials • Caulking materials (noncombustible) • Fireplace surround materials (noncombustible) • Insulation (for packing around gas-line penetration holes) CODES Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223.1 or NFPA 54 which can be obtained from The American National Standards Institute, Inc. (1430 Broadway, New York, NY, 10018) or National Fire Protection Association, Inc. (Batterymarch Park, Quincy, MA, 02269). COMBUSTION AND VENTILATION AIR Heaters installed in these appliances shall not be installed in a confined space. Heaters installed in these appliances may be located in unusually tight construction provided the space is unconfined, or if confined, is provided with two permanent openings communicating directly with an additional room(s) of sufficient volume so that the combined volume of all connected spaces meets the criteria for an unconfined space, (National Fuel Gas Code ANSI Z223.1 1992, Section 5.3). Generally 50 ft 3 per 1,000 BTU input of all operating appliances in the space. 3 The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 ft 3 per 1,000 BTU/Hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 ft 3 per 1,000 BTU/Hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. Unusually tight construction is defined as construction where: a. Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed, and b. Weather stripping has been added on operable windows and doors, and c. Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. Use the following equations to determine if you have a confined or unconfined space. 1. Determine the volume of space — ft 3. Length x Width x Height = _____ ft 3 (Include adjoining rooms with doorless passageways or ventilation grills between rooms). Example: 24' (L) x 16' (W) x 8' (H) = 3072 ft 3 2. Divide the volume of space by 50 ft 3 to determine the maximum BTU/Hr the space can support. (volume of space – ft 3)/ 50 ft 3 = (Maximum BTU/Hr the space can support) 3. Add the BTU/Hr of all the fuel burning appliances in the space. Vent-Free heater Gas appliance #1* Gas appliance #2 ________ ________ +________ BTU/Hr BTU/Hr BTU/Hr Total =________ BTU/Hr Example: Vent-free heater 26,000 Gas appliance #1 40,000 (water heater) Total = 66,000 BTU/Hr BTU/Hr BTU/Hr * Do not include direct-vent gas appliances. Direct-vent is sealed combustion and draws combustion air from the outdoors. 4. Compare the maximum BTU/Hr the space can support with the actual amount of BTU/Hr used. _________ BTU/Hr (max. the space can support) _________ BTU/Hr (actual amount of BTU/Hr used) Example: 61,440 BTU/Hr (max. the space can support) 66,000 BTU/Hr (actual amount of BTU/Hr used) The space in the above example is a confined space because the actual BTU/Hr used is more than the maximum BTU/Hr the space can support. You must provide additional fresh air. WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1 1992, Section 5.3 or applicable local codes. Example: 3072 ft 3 / 50 ft 3 = 61.44 or 61,440 BTU/Hr the space can support. 4 NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. Your options are: a. Rework equations adding the space of adjoining room(s). If the extra volume provides an unconfined space, then remove door or add ventilation grills between rooms. Refer to National Fuel Gas Code, ANSI Z223.1 1992, Section 5.3. b. Vent room directly to the outdoors. Refer to National Fuel Gas Code, ANSI Z223.1 1992, Section 5.3. c. Install a lower BTU/Hr heater, such as a 21,000 BTU/Hr, to make the area an unconfined space. If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, then the space is an unconfined space. You will need no additional fresh air ventilation for an unconfined space. COLD CLIMATE INSULATION For cold climate installations, seal all cracks around the appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside cavities between studs and under floor on which the appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced fiberglass insulation. If the fireplace is being installed on a cement slab, in cold climates, a sheet of plywood or other raised platform can be placed underneath to prevent conducting cold up into the room. It also helps to sheetrock inside surfaces and tape for maximum air tightness and caulk firestops. NEW YORK CITY, NEW YORK (MEA) Installation of these fireplaces are approved for installation in New York City in the US state of New York. Note: The following requirements reference various Massachusetts and national codes not contained in this document. (e)Unvented propane or natural gas-fired space/room heaters shall be prohibited in bedrooms and bathrooms. Requirements for the Commonwealth of Massachusetts (f)Space/room heaters shall be properly sized for the room or space of installation, but shall not exceed a maximum of 40,000 BTU input per room or space. Un-vented Room Heaters shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00 through 7.00: (a) Permits and Inspections: In addition to complying with 248 CMR 3.05 the following requirements must be satisfied: 1. A permit shall be obtained from the head of the fire department and the local or state gas inspector having jurisdiction for the installation of all unvented propane or natural gas-fired space/room heaters. 2. The permits shall be conditioned upon final inspection and approval of installation by the head of the fire department and the local or state gas inspector having jurisdiction. 3. A copy of the manufacturer’s installation/operating literature shall be submitted with each permit application. 4. Before operation, the Head of the Fire Department and the local or state gas inspector shall inspect the installation for compliance with 527 CMR (Board of Fire Prevention Regulations) and 248 CMR (Board of State Examiners of Plumbers and Gas Fitters). 5. A final inspection by the state or local gas inspector of the unvented space/room heater shall not be performed until proof is provided that the head of the fire department having jurisdiction has granted a permit. (b)Unvented propane or natural gas-fired space/room heaters shall conform to ANSI Z21.11.2, be equipped with an oxygen depletion safety (ODS) shutoff system and be Product-approved in accordance with 248 CMR. (c)Unvented propane or natural gas-fired space/room heaters shall be installed in accordance with their listings and the manufacturer’s instructions. Proper clearances to combustibles shall be maintained. In no case shall the clearances be such as to interfere with combustion air and accessibility. (g)In occupancies with an unvented propane or natural gas-fired space/room heater, no less than one listed carbon monoxide detector that is installed in accordance with the manufacturers instructions shall be installed and maintained near the space where the heater is located. 1. Any building wherein the heater is to be installed shall, as a precondition to such installation, have working smoke detectors installed and maintained in accordance with the requirements of 780 CMR (State Board of Building Regulations and Standards) in effect at the time of construction or; 2. If no requirement was in effect at the time of construction the smoke detector shall be compliant and installed as provided for in M.G.L. c. 148, § 26E. (h)In rooms and buildings served by an unvented propane or natural gas-fired space/room heater, a primary source of heat, which is operable, shall be permanently installed and maintained in the building in accordance with 105 CMR (Department of Public Health). (i)Sellers of unvented propane or natural gas-fired space/room heaters shall provide to each purchaser a copy of 527 CMR 30.00 upon sale of the unit. • Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts. • The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length. • The individual manual shut-off must be a T-handle type valve. (d)Installations shall be of a permanent type, with a permanently piped fuel supply in accordance with 248 CMR. LPG appliances shall be subject to the storage requirements in accordance with 527 CMR 6.00. Portable unvented propane or natural gas-fired space/room heaters shall be prohibited. NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. 5 LOCATION OF FIREBOX Carefully select the best location for installation of your built-in Vent-Free firebox. The following factors should be taken into consideration: • Clearance to side wall, ceiling, woodwork and windows. • Location must not be affected by drafts caused by kitchen exhaust fans, return air registers for forced air furnaces/air conditioners, windows or doors. • Installation must provide adequate ventilation and combustion air. • Do not install this firebox in a sleeping room or bathroom. WARNING Do not install these built-in VentFree fireboxes in sleeping quarters, or in recreational vehicles. Do not install these appliances: • Where curtains, furniture, clothing or other flammable objects are less than 42" from the front of the Vent-Free room heater. • In high traffic areas. • In windy or drafty areas. • Minimize modifications to existing construction. See Figure 1 for location suggestions. Figure 2 Ceiling clearance: The ceiling must be at least 40" from the top of the firebox opening (Figure 2 ). RECOMMENDATION: Use high temperature finish material for the mantels and/or use the canopy (for UVFRC-3628, UVFRC-3628H, UVFRC-4228 & UVFRC-4228-H). CAUTION Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this fireplace. Optional Hearth Extension Noncombustible material: Noncombustible materials, such as slate and marble, must be at least 1/2" thick and may be used without restriction above the firebox opening, to the sides or as a hearth extension, so long as they do not obstruct vent openings for heat circulating models. • Never obstruct the front opening of the Vent-Free firebox or restrict the flow of combustion and ventilation air. WARNING 16" WARNINGS • Location should be out of high traffic areas and away from furniture and draperies due to heat from firebox. Do not install in the vicinity where gasoline or other flammable liquids may be stored. The Vent-Free firebox must be kept clear and free from these combustible materials. 40" Not to Scale Combustible Wall Clearance Above Appliance (all models) Figure 1 Finished Wall Clearances Ensure the minimum clearances shown in Figures 2 through 6 are maintained. Left and right clearances are determined when facing the front of the firebox. Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a fire hazard. Sidewall clearances: The sides of the firebox opening must be at least 16" from any combustible wall (Figure 2 ). Non-Combustible Material 3" Min. (shaded area) Shown with Canopy Installed (required on UVF-36 only) NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. Top of Appliance Fireplace Opening Figure 3 6 Header Top StandOff Spacer (on appliance) Combustible Mantel and Trim Clearance Combustible Mantel and Trim Clearance Model UVF-36 WITH Canopy Installed Models UVFRC-3628 and UVFRC-4228 WITHOUT Canopy Installed Canopy is required on all installations for this model only. Canopy is optional on these models Safe Zone Safe Zone Combustible Mantel and Trim Combustible Mantel and Trim 18” 24” 17” 23” 16” 22” 15” 21” Combustible Material (wall) Coordinate in ()Example 14” 20” 13” Combustible Material (wall) 18” 12” 11” Header 17” Header 10” Top Spacer on Appliance 16” Top Spacer on Appliance 9” 8” 7“ 6” 5” 4” Non-Combustible Material 3” Min. 3” Example Example 19” Coordinate in ()Example 10” 9” 8” 7” 6” Non-Combustible Material 3” Min. Example Top of Appliance Top of Appliance Example Top of Firebox Opening Canopy Top of Firebox Opening Screen Screen EXAMPLE: If you choose to install a mantel that projects 5", you will need to install it so that the bottom of the mantel and trim is approximately 13" or more above Firebox opening (see coordinate in shaded area above). EXAMPLE: If you choose to install a mantel that projects 7", you will need to install it so that the bottom of the mantel and trim is approximately 19" or more above Firebox opening (see coordinate in shaded area above). Figure 4 Figure 6 Combustible Mantel and Trim Clearance Models UVFRC-3628 and UVFRC-4228 WITH Canopy Installed Canopy is optional on these models Noncombustible material (minimum requirements) with wood mantel or other combustible projections: To install the firebox with a wood mantel, shelf or other combustible projection above firebox opening. Refer to Figures 4, 5 & 6. Safe Zone WARNING Combustible Mantel and Trim 16” 15” Coordinate in ()Example 14” Combustible Material (wall) 13” 12” The canopy must be in place to be in compliance with the clearances specified in Figures 4 & 5. Do not remove or replace canopy, only use canopy supplied or offered for these fireboxes (see Pages 16 & 17). Do not use any canopy which may be provided with the decorative type Vent-Free room heater. Header Example 11” Top Spacer on Appliance 10” 9-1/2” 6” 5” 4” 3” 2” Non-Combustible Material 3” Min. Top of Appliance If your mantel profile is unsafe, you may either: • Raise the mantel to an acceptable height, or • Remove the mantel. Example Top of Firebox Opening Canopy Screen EXAMPLE: If you choose to install a mantel that projects 4", you will need to install it so that the bottom of the mantel and trim is approximately 13" or more above Firebox opening (see coordinate in shaded area above). Floor clearance: These fireplaces may sit directly on a combustible surface. The appliance should be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materials. However, if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal or wood barrier covering the entire bottom surface must be used. Figure 5 NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. 7 ASSEMBLY STEPS Consult all local codes. Notes: • Illustrations shown in this manual reflect “typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due to individual design preferences. However, always maintain minimum clearances to combustible materials and do not violate any specific installation requirements. Refer to the Framing Specifications Figures on Page 11. Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code, NFPA 54 - latest edition (USA) or B149 - latest edition (Canada). Never use galvanized or plastic pipe. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. We recommend that a qualified individual such as a plumber or gas fitter be hired to correctly size and route the gas supply line to the appliance. Installing a gas supply line from the fuel supply to the appliance involves numerous considerations of materials, protection, sizing, locations, controls, pressure, sediment, and more. Certainly no one unfamiliar and unqualified should attempt sizing or installing gas piping. • The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence. Step 1. Position firebox prior to framing or into prepared framing. Step 2. Field wire the main power supply to the appliance if a blower kit is to be installed (at the time of installation or a later date). An optional junction box kit and blower kit is required (see Page 15 for ordering information). Follow the installation and wiring instructions on Pages 12 through 14). Electrical connections should only be performed by an experienced, licensed/certified tradesman. Step 3. Plumb gas line. (Gas connections should only be performed by an experienced, licensed/certified tradesman). Step 4. Install decorative type Vent-Free room heater per the instructions provided with the Vent-Free room heater. Step 5. Complete finish wall material, surround and optional hearth extension to your individual taste. INSTALLATION Install 1/2" min. to 1-1/2" max. inside diameter approved gas line through the firebox wall for connection to the Vent-Free room heater inside the firebox. Connect the gas line before the firebox is enclosed in the finished wall. Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced fiberglass insulation. Ensure that a sediment trap is installed in the existing gas line, if not, install a sediment trap upstream of the heater to prevent moisture and contaminants from passing through trap to the heater controls and burners. Failure to do so could prevent the heater from operating reliably. An external regulator must be used on all propane (L.P.G). heaters, in addition to the regulator fitted to the heater, to reduce the supply tank pressure to 13" W.C. (maximum). Any copper tubing used to supply propane (L.P.G). from the tank must be internally tinned. WARNING Gas Line Installation CAUTION Plumbing connections should only be performed by a qualified, licensed plumber. Main gas supply must be off when plumbing gas line to fireplace or performing service. 8 Remove the gas line access cover plate on either the left or right side of the fireplace (see Figure 8 showing locations). Check Gas Type: The gas supply must be the same as stated on the heater’s rating plate. If the gas supply is different, DO NOT INSTALL the heater. Contact your dealer for the correct model. IMPORTANT Hold heater regulator with a wrench to prevent movement when connecting to inlet piping. WARNING Connecting directly to an unregulated propane (L.P.G). tank can cause an explosion. IMPORTANT Pack unfaced fiberglass insulation material (not provided) around the gas line access hole on appliance and all exterior gas line penetration holes. TEST ALL CONNECTIONS FOR GAS LEAKS (FACTORY AND FIELD) Test all gas joints from the gas meter to the gas heater regulator for leaks using a gas leak test solution (also referred to as bubble leak solution). Note: Using a soapy water solution as a leak detection solution is not recommended because the soap residue that is left on the pipes/fittings can result in a false-positive leak detection reading if a gas leak sniffer is used. Soap residue can also result in corrosion over time. DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS. Leak Test Procedure: Turn on gas supply and test for gas leaks using a gas leak test solution. A. Light the appliance (refer to the lighting instructions label provided with gas logs). B. Brush all joints and connections with the gas leak detection solution. If bubbles are formed, or gas odor is detected, turn the gas control knob (off/pilot/on) to the “OFF” position. Either tighten or refasten the leaking connection, then retest as described above. C. When the gas lines are tested and found to be leak free, rinse off the leak testing solution from gas line fittings. NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. Firebox Framing Construct firebox framing following Figures 9 through 11 and Table 1 on Page 11 for your specific installation requirements. Refer to Figure 8 on Page 10 for firebox dimensions. The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. Do not place firebox on carpeting, vinyl or other soft floor coverings. It may, however, be placed on flat wood, plywood, particle board, metal or other hard surfaces which extend the full width and depth of the enclosure. Be sure firebox rests on a solid continuous floor or platform with appropriate framing for support and so that no cold air can enter room from under the firebox. CAUTION Do not block the heat-circulating air inlets and outlets on these fireboxes. Doing so may create a potential fire hazard. The firebox may be positioned and then the framing built around it, or the framing may be constructed and the firebox positioned into the opening. Usually, no special floor support is needed for the firebox, however, to be certain: 1. Estimate the total weight of the firebox system and surround materials such as marble, brick, stone, etc., to be installed (see Product Referance Table on Page 10 for appliance weight). 3. Note the floor construction, i.e. 2" x 6", 2" x 8" or 2" x 10", single or double joists, type and thickness of floor boards. Note: The nailing flange and the area directly behind the nailing flange is exempt from the clearances described on the firebox clearance label. 4. Use this information and consult your local building code to determine if you need additional support. Step 4. To safely operate the heater with consideration of the mantel clearances the canopy must be installed (Model UVF-36 Only). If you plan to raise the firebox, build the platform assembly then position firebox on top. Secure the platform to the floor to prevent possible shifting. Firebox Installation Step 1. Frame these appliances as illustrated in Figures 9 through 11. All framing details must allow for a minimum clearance to combustible framing members as shown in Figures 2 through 6. Also refer to appliance specifications on Page 10 . Headers may be in direct contact with the appliance top spacers but must not be supported by them or notched to fit around them. All construction above the appliance must be self supporting, DO NOT USE THE APPLIANCE FOR STRUCTURAL SUPPORT. IMPORTANT Under no circumstances shall the firebox top spacers be removed or modified (see Figure 8). The header may be in direct contact with the top spacers but must not be supported by them or notched to fit around them. Top Spacer Note: The framed depth from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the depth must be measured from the drywall surface. It is important that this dimension be exact. 8d Nail Step 2. Level the firebox by checking the top edge of the firebox. Shim if necessary. Step 3. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face. Use 8d nails (see Figure 7). Figure 7 2. Measure the square footage of the floor space to be occupied by the system and surrounds. NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. 9 SPECIFICATIONS Dimensions - Inches (millimeters) Model No. A B C D E F G H J K L M N P *Q UVF-36 36 (914) 24 (610) 41-3/4 (1061) 37-1/4 (946) 23-1/2 (597) 20 (508) 3 (76) 7-3/8 (187) 15-7/8 (403) 7-1/2 (190) 11-15/16 (303) 1-5/16 (33) 5-1/2 (140) 30-5/16 (770) 29-5/8 (753) UVFRC-3628 & UVFRC-3628-H 36 (914) 28 (711) 41-3/4 (1061) 41-1/4 (1048) 23-1/2 (597) 20 (508) 3 (76) 8-3/8 (213) 15-7/8 (403) 7-1/2 (190) 11-15/16 (303) 1-5/16 (33) 5-1/2 (140) 34-5/16 (872) 33-5/8 (854) UVFRC-4228 & UVFRC-4228-H 42 (1067) 28 (711) 47-3/4 (1213) 41-1/4 (1048) 29-1/2 (749) 20 (508) 3 (76) 8-3/8 (213) 15-7/8 (403) 7-1/2 (190) 11-15/16 (303) 1-5/16 (33) 5-1/2 (140) 34-5/16 (872) 33-5/8 (854) Product Reference Information Cat. No. Model Ship. Weight (lbs) * A canopy comes standard and is required for model UVF-36. The factory-supplied canopy must be installed on the firebox for safe operation for model UVF-36 in all installations. This part is optional for models UVFRC-3628, UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H. Shipping Volume H1957 UVF-36 150 lbs 20 Cu. Ft. H1953 UVFRC-3628 200 lbs 22 Cu. Ft. H1954 UVFRC-3628-H 200 lbs 22 Cu. Ft. H1955 UVFRC-4228 230 lbs 26 Cu. Ft. H1956 UVFRC-4228-H 230 lbs 26 Cu. Ft. E Junction Box F N Top View M Top Stand-Off Spacers (4 places) 1 (25) 7-1/16 (179) Top of Firebox Opening 3-9/16 (90) G * Canopy B Gas Line Access Both Sides D P *Q Bottom of Firebox Opening Top of Bottom Refractory J 6-3/16 (157) 5-3/4 (146) K L A C Right Side View Front View Figure 8 10 H NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. Access Opening for Junction Box - Right Side Only (remove the knock-out before installing J-Box). J-Box / Electrical Kit is not provided with appliance. FRAMING SPECIFICATIONS Framing Dimensions Corner Installation Opening UVF-36 UVFRC-3628 & UVFRC-3628-H UVFRC-4228 & UVFRC-4228-H A 42-1/4" (1073) 42-1/4" (1073) 48-1/4" (1226) B 40-1/4" (1022) 44-1/4" (1124) 44-1/4" (1124) C 23-9/16" (599) 23-9/16" (599) 29-9/16" (751) D 11-1/4" (286) 11-1/4" (286) 14-1/4" (362) E 63-1/2" (1613) 63-1/2" (1613) 69-1/2" (1765) F 31-3/4" (807) 31-3/4" (807) 34-3/4" (883) G 20-1/2"( 521) 20-1/2"( 521) 20-1/2"( 521) H 44-3/16" (1122) 44-3/16" (1122) 49-1/8" (1248) Back Wall Of Chase/Enclosure Including Finishing Materials If Any This Figure corresponds to Table 1 D F H G C A Table 1 - This Table corresponds to Figures 9, 10 & 11 E Rough Framing Face (Unfinished Shown) Figure 10 Parallel Installation Rough Framing Face (Unfinished Shown) Back Wall Of Chase/Enclosure Including Finishing Materials If Any C Header G This Figure corresponds to Table 1 B A Figure 9 A Figure 11 This Figure corresponds to Table 1 Canopy Kit Installation (see ordering information on Page 16) NOTE: A canopy comes standard and is required for model UVF-36. The factory-supplied canopy must be installed on the firebox for safe operation for model UVF-36 in all installations (this part is optional for other models). See Figure 13. These canopy kits are design to be fitted to the face of the appliance directly above the firebox opening. In addition to providing an aesthetically pleasing appearance to your appliance, the canopy reduces heat effects to decorative mantels and finish materials located directly above the fireplace and reduces the Mantel / Trim clearances (see Figures 4, 5 & 6 on Page 7). Removing Screens & Rods: Remove screws (see dotted lines). Pull out rods from locating holes on side of firebox opening. Reinstalling Screens & Rods: Insert rods into corresponding locating holes on sides of firebox opening, then reinstall screws as shown. Please read this entire manual and understood thoroughly before proceeding with the installation of these kits. Step 1. Using a 5/16" nut driver or socket, remove the screen and rod assemblies as shown in Figure 12. Step 2. Align the canopy with the holes in the side frames as shown in Figure 13. Install three screws as shown in Figure 13. Make sure canopy is level and secure. Step 3. Reinstall screen and rod assemblies (see Figure 12). Figure 12 NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. 11 IMPORTANT Figure 13 OPTIONAL EQUIPMENT Blower Kits The FBK-100 Blower Kits are used when a wall-mounted ON/OFF blower switch is desired, and the FBK-200 Blower Kits are used when a wall-mounted variable speed blower control (rheostat) is desired. A Junction Box / Electrical Kit is also required to install these kits (purchased separately - see Page 15). * The Junction Box / Electrical Kit is not included. See Page 15 for ordering information. Figure 15 Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. * Wall-mounted ON/ OFF Blower Switch or Variable Speed Control Switch. HOT SIDE OF RECEPTACLE Black Blower Motor NEUTRAL SIDE OF RECEPTACLE Grounded to Appliance The installation instructions for installing these blower kits are on Pages 12 through 14. Also see the installation instructions provided with the blower kits (Form #750,028M). For electrical requirements, refer to Figures 14, 15 & 16. Tab Intact Junction Box Plug blower into this receptacle Motor Plug Green Ground Screw Field Wired Factory Wired Blower Receptacle Ground 120V Appliance Junction Box Note: If any of the original wire as supplied must be replaced, it must be replaced with type AWM 105 degree C - 14 gage wire. Figure 14 *An ON/OFF Wall Switch is used with the FBK-100 kit (field provided or sold separately - order P/N 85L87); A Variable Speed Control (provided) is used with the FBK200 kit. The installation of these kits also require a Junction Box / Electrical Kit, not included. See Page 15 for ordering information. Note: If any of the original wire as supplied must be replaced, it must be replaced with type AWM 105 degree C - 14 gage wire. Figure 16 12 120V, 60HZ, 1PH BLOWER CONTROL CIRCUIT WIRING CAUTION The blower is installed beneath the firebox. Room air is drawn in through the side slots of the fireplace, heated as it passes across the firebox, and discharged through the upper area of the firebox opening. If the blower kit is to be installed at the time of installation or at a later date, the main power supply must be installed at the time of installation. This will require that the electrical connections must be made BEFORE the firebox is framed and enclosed in the finished walls. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply and connect to electrical receptacle wires and wall switch or rheostat. Blower 120 VAC Black Side View The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the national electrical code, ANSI/NFPA 70-(latest edition). (In Canada, the current CSA C22-1 Canadian Electrical Code). * Junction Box Bend blower mounting tabs up to secure Tie a loose knot in power blower in place cord to take up slack Ground - Green Neutral - White Canopy The Ground Lead must be connected to the green screw (located on the junction box). Failure to do this could result in an electrical short or shock injury. Top View * Electrical Outlet NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. Installation Instructions FBK-100 or FBK 200 Blower Kits and JBK Junction Box Kit Cover Plate J-Box & Receptacle IMPORTANT All electrical wiring must be performed by licensed Electricians. Electrical wiring must comply with the National Electrical Code ANSI/ NFPA 70 - latest edition Step 1. Follow the instructions below for the model you are installing: Remove knock-out (strain relief bushing presses into this hole around romex wires - see Step 8 on Page 14). Model UVF-36: Screw Using a screwdriver remove the screw from the blower access panel as shown in Figure 18. Slide the panel to the right until the flange clears the opening. Remove the panel and set aside. Strain Relief Bushing Figure 19 - Junction Box Kit (all models) Models UVFRC-3628, UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H: Lift out the bottom refractory panel (see Figure 17). Step 2. Remove the rectangular knock-out (for J-Box) on the right side of unit (see Figure 8 for location). Install the Junction Box & Electrical outlet below the firebox floor into the rectangular opening on the right side cabinet panel where you removed the knock-out (see Figures 20 & 21). The Junction Box / Electrical Kit is sold separately (see Page 15 for ordering information). J-Box & Electrical Outlet J-Box Flange Firebox floor Note: Pass the wires through the hole, then squeeze the J-Box flanges together to fit into opening. Step 3. Loosely tie a knot in the power cord to take up slack (see Figure 22). Step 4. Locate the tabs shown in Figure 23. Position the blower assembly so that the tabs (located on the cabinet base) are seated in the notches of the blower bracket. Bend the tabs over to secure the blower assembly (see Figure 24). Install into side wall rectanular opening Figure 20 - Model UVFRC-4228 Shown J-Box Flanges Right Outside Cabinet Panel Step 5. Plug power cord into the electrical outlet as illustrated in Figure 15. Lift Out Bottom Refractory Panel J-Box & Electrical Outlet Wires Models: UVFRC-3628, UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H Figure 17 Firebox floor Screw Blower Access Panel Remove screw, then lift out blower access panel. Figure 18 - Model UVF-36 Figure 21 NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. 13 Step 8. Ensure that power supply wires are NOT "live" before making these connections). Install J-Box Cover Plate as follows: Feed the * Romex wires (or other equivalent plastic insulated wire - Refer ANSI/NFPA 70 - National Electrical Code - Latest Edition) through the J-Box Cover retangular opening, then connect to the J-box wires. The strain relief bushing should be pressed into the knock-out on J-box cover around the Romex (this will provide protection to the wires and prevents strain against connections from J-box). See Wiring Diagram - Figure 16. Install the cover plate over J-Box opening on appliance as shown in Figure 25. Model UVFRC-4228 Shown Firebox floor Note: Wire connections should be positioned inside of the appliance. Loose knot in power cord to take up slack * Romex is a plastic insulated wire from power supply - sometimes called non-metallic sheath. Figure 22 Model UVFRC-4228 Right Side Panel of Firebox Cabinet Base J-Box opening on appliance Locating Tabs Use screw provided and secure in place as shown Figure 23 - UVFRC-4228 Shown Screw The notched side of cover plates goes inside firebox panel Cover Plate Figure 25 - Installing J-box Cover Plate - All Models Step 9. Follow the instructions below for the kit you are installing: FBK-100 Kits - Install a field-provided (or P/N 85L87) ON/OFF wall switch in a convenient location on a wall, near the fireplace. Bend Locating Tabs Over (into notches) FBK-200 Kits - Install the kit-provided variable speed control (rheostat) in a convenient location on a wall, near the fireplace. Figure 24 - UVFRC-4228 Shown Step 10. Follow the instructions below for the model you are installing: Step 6. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply to the right side of appliance. Step 7. Locate the J-Box cover (provided in J-Box Kit). Remove the round knock-out (see Figure 19). 14 Model UVF-36: Reinstall the blower access panel that was removed on Step 1 (see Figure 18). Models UVFRC-3628, UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H: Reinstall the bottom refractory panel that was removed on Step 1 (see Figure 17). NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. APPROVED ACCESSORIES AND COMPONENTS FIREBOX FINISHES There are a wide variety of “finished looks” for your built-in Vent-Free firebox from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like marble, stone, tile, brick, etc. may overlap the black front facing. Seal all joints between the black facing and wall surrounds to prevent air intrusion. Use noncombustible caulking material only to seal the black metal facing to the surround material on the finished wall. See Figures 3 & 26. Raised Hearth Extension A hearth extension may be used but is not required for these appliances. A raised hearth extension may be used as shown in Figure 26. Decorative Arch Screen Panel Kit This attractive screen door is easy to install and enhances the appearance of the appliance. Combustible Wall Decorative Screen Door Panel Kit Cat. No. Non-Combustible Wall (see Figure 4) Model Where Used H1959 ASD3624-TI H1960 ASD3628-TI UVF-36 UVFRC-3628 & UVFRC-3628-H H1961 ASD4228-TI UVFRC-4228 & UVFRC-4228-H (ref. Form # 750,209M) Fireplace Opening Decorative Volcanic Stone Cat. No. Model No. Description 80L42 FDVS Bag of Volcanic Stone (ref. Form #750,010M) Decorative Volcanic Stone The decorative volcanic stone, Model FDVS, can be used to enhance the look of your appliance. Order model FDVS for replacement of stone when needed. Spread the decorative volcanic stone evenly around the bottom of the firebox. Raised Hearth Extension (combustibles allowed. No carpet or vinyl) Firebox Floor 5-3/4" Max.* * From Base to Bottom of Firebox Opening (floor) Combustible Platform Base SIDE VIEW Junction Box / Receptical Kit Figure 26 - Raised Hearth Extension Cat. No. H1958 Model No. Description JBK Junction Box / Electrical Kit (ref. Form #750,203M) NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. 15 APPROVED ACCESSORIES AND COMPONENTS The variable speed control rheostat is included with FBK-200 models only * Forced Air Blower Kits Cat. No. Model No. 80L84 FBK-100 Blower, Standard (single speed) 80L85 FBK-200 Blower, Variable Speed (w/wall-mounted switch) 94L89 FBK-100-36 Blower, Standard, 36 Pack 94L90 FBK-200-36 Blower Kit - Variable Speed with Wall Switch 36 Pack Charcoal Canopy Cat. # Model Models Where Used H1989 FC36 UVFRC-3628, UVFRC-3628-H (UVF-36 standard part) H1990 FC42 UVFRC-4228 & UVFRC-4228-H (ref. Form #750,195M) An ON/OFF wall switch can be used with the FBK-100 models (field supplied or order P/N 85L87 Wall Switch Kit, shown below) Description (ref. Form # 750,028M) * The installation of these kits also require a Junction Box / Electrical Kit, not included. See ordering information below Blower Kit The FBK-100 blower provides for a constant velocity forced air circulation feature for your appliance. The FBK-200 assembly with variable speed wall switch provides a forced air circulation feature for your appliance. PA I N T Outside Air Gate & Duct Kit Cat. No. Model No. Description H3991 OAK-UVFRC Outside Air Gate & Duct Kit Touch-Up Paint Kit ON/OFF Wall Switch Kit Repair of minor scratches and discoloration of the appliance charcoal painted surfaces may be accomplished with the touch-up paint kit. The ON/OFF wall switch kit may be used to control the blower operation, if FBK100 blower kit is installed. Install the ON/OFF wall switch in a convenient location near the fireplace. (ref. Form #750,206M) Outside Air Gate & Duct Kit These kits have an air gate assembly, 4" diameter duct and a termination hood. The air gate allows adjustment of the amount of outside air delivered to the fire for combustion. Only one kit, located on the right side of the fireplace, is required. Touch-Up Paint Kits Cat. No. Model No. 90L74 TPK-C Description Touch-Up Paint (Charcoal) White Wall Switch Kit Cat. No. Model No. Description 85L87 FWSK ON/OFF Wall Switch Kit (ref. Form # 504,216M) (ref. Form #850,021M) SERENE HEAT ® VENT-FREE GAS LOG SETS - MANUAL / PIEZO IGNITION, STANDING PILOT Cat. # Model Description BTU/hr Input Models Where Used H2053 SHGL-18MN-R 18” Vent-Free Gas Log Set, Natural 25,000 - 36,000 UVF-36, UVFRC-3628 & UVFRC-3628-H H2054 SHGL-18MP-R 18” Vent-Free Gas Log Set, Propane 27,000 - 36,000 UVF-36, UVFRC-3628 & UVFRC-3628-H H2055 SHGL-24MN-R 24” Vent-Free Gas Log Set, Natural 26,000 - 39,000 UVF-36, UVFRC-3628 & UVFRC-3628-H H2056 SHGL-24MP-R 24” Vent-Free Gas Log Set, Propane 31,000 - 39,000 UVF-36, UVFRC-3628 & UVFRC-3628-H (ref. Form #903,623M) VENT-FREE GAS LOG SETS - MANUAL / PIEZO IGNITION, STANDING PILOT 16 Cat. # Model Description BTU/hr Input H2126 VFGL18-MSN-4 18” Vent-Free Gas Log Set, Natural 14,000 - 25,000 UVF-36, UVFRC-3628 & UVFRC-3628-H H2127 VFGL18-MSP-4 18” Vent-Free Gas Log Set, Propane 14,000 - 25,000 UVF-36, UVFRC-3628, UVFRC-3628-H H2128 VFGL24-MSN-4 24” Vent-Free Gas Log Set, Natural 17,000 - 32,000 UVF-36, UVFRC-3628 & UVFRC-3628-H H2129 VFGL24-MSP-4 24” Vent-Free Gas Log Set, Propane 17,000 - 32,000 UVF-36, UVFRC-3628 & UVFRC-3628-H H2130 VFGL28-MSN-4 28” Vent-Free Gas Log Set, Natural 17,000 - 32,000 UVFRC-4228 & UVFRC-4228-H H2131 VFGL28-MSP-4 28” Vent-Free Gas Log Set, Propane 17,000 - 32,000 UVFRC-4228 & UVFRC-4228-H NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. Models Where Used REPLACEMENT PARTS An exploded view of the firebox with numbered parts and a replacement parts list can be found on the Page. Normally, all parts should be ordered through your distributor or dealer. Parts will be shipped at prevailing prices at time of order. When ordering repair parts, always give the following information: 1. The *model number of the firebox. 2. The *serial number of the firebox. 3. The part number. 4. The description of the part. 5. The quantity required. 6. The installation date of the firebox. * Note: The model and serial number can be found on the rating label located on the bottom left front corner of the appliance. If you encounter any problems or have any questions concerning the installation of a Vent-Free heater in this system, please contact your distributor or dealer or visit our website at www.lennox.com.. 2 3 4 1 5 6 UVF-36 No. Description Gas Fireplace Assembly Part No. UVFRC-3628 Qty. Part No. UVFRC-3628-H Qty. Part No. Qty. UVFRC-4228 UVFRC-4228-H Part No. Qty. Part No. Qty. - - - - - - 1. Firescreen H3814 2 H3820 2 H3820 2 H3827 2 H3827 2 2. Rod, Screen H3815 2 H3815 2 H3815 2 H3828 2 H3828 2 3a. Refractory, Left H3809 1 H3817 1 H3822 1 H3817 1 H3830 1 3b. Refractory, Right H3810 1 H3816 1 H3821 1 H3816 1 H3829 1 4. Refractory, Rear H3811 1 H3819 1 H3823 1 H3824 1 H3831 1 5. Refractory, Bottom - - H3818 1 H3818 1 H3825 1 H3825 1 6. Canopy H1989 1 H1989 1 H1989 1 H1990 1 H1990 1 NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. - - 17 NOTES 18 NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. NOTES NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE. 19 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2006 by LHP P/N 700,032M REV. B 05/2006 LHP 1110 West Taft Avenue • Orange, CA 92865