Download Siemens SISTORE MX User manual
Transcript
Configuring user and access management 13.6 Enabling operating panel control NOTE: The Operating console group field is only visible if the CKA 4810 or CKA 4820 driver is installed. Further information on this can be found in the SISTORE MX NVS Installation Manual. Operating console group field on the System tab Fig. 90 Prerequisites z The SISTORE MX NVS software has been started. See Section "Starting SISTORE MX NVS and logging in“, page 17. z The SISTORE MX NVS software is in configuration mode. See Section "Opening configuration mode", page 18. 124H 410H 124H 1243H 124H 1. Select the System tab. 2. Mark the checkbox Operating console (see Fig. 90, page 103). Î The Operating console group field will be enabled. 3. Select the interface to which your operating panel is connected from the COM dropdown field. 4. Enter a value in milliseconds in the Button delay text field. Î If no keyboard input takes place within the specified time, the entry is considered complete. 5. Click Apply. Î Your settings will be saved. 41H 1245H 1246H 1247H 103 Siemens Building Technologies Fire Safety & Security Products 03.2009