Download Cisco 12810 Specifications
Transcript
Alarm Card and Alarm Display Overview Figure 2 Alarm Cards and Alarm Display Blower module Alarm display Line card and GRP card cage L I N E C A R D L I N E C A R D L I N E C A R D L I N E C A R D L I N E C A R D L I N E C A R D L I N E C A R D L I N E C A R D R P C A R D 1 R P C A R D 0 Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot 0 1 2 3 4 5 6 7 8 9 C S C 1 S F C 0 S F C 1 S F C 2 PEM1 S F C 3 S F C 4 A L A R M 0 A L A R M 1 PEM2 50397 Switch fabric and alarm card cage C S C 0 The alarm cards and alarm display perform four functions: • Hardware implementation of the alarm system • OK/FAIL status indication for the CSCs and SFCs • Power system monitoring • Redundant generation of the 5 VDC maintenance bus (MBus) supply voltage for the line cards The display indicator LEDs, alarm relays, and external alarm relay connectors are located on a separate card in order to accommodate the mechanical design requirements of the router enclosure. The external alarm display assembly is mounted on the front of the chassis just above the horizontal cable-management tray (Figure 3). The alarm display assembly is sometimes referred to as the alarm display card or alarm display. The power system monitoring functions are located in the alarm card MBus module. Cisco 12010, Cisco 12410, and Cisco 12810 Router Clock and Scheduler, Switch Fabric, and Alarm Card Replacement Instructions OL-13810-01 5