Download Miele PW 6101 Programming instructions
Transcript
Programming 12. Dispensing phase 1 14. Agitation from level This option is used for specifying the dispensing procedure for a max. of 6 dispenser pumps. This defines drum agitation in the programme block after the first water intake. Selection choice: – No Selection choice: – Automatic – User defined Dispensing does not take place. – User defined Dispenser pumps 1 dispenser pump per dispensing can be selected from D1 to D 13 Dispensing amount (depending on dispensing method selected) 0 to 999 ml or 0 to 50 ml/l or 0 to 50 ml/kg Dispensing delay 0 to 999 sec. – X with dispensing type set to "No" Time 0, 15 to 59 sec 0 to 99 min. Rhythm No Normal 12/3 sec. Wash/Pause Gentle 5/10 sec. Wash/Pause Gentle+ 3/27 sec. Wash/Pause User defined On: 2 to 99 sec. Off: 2 to 99 sec. rpm No Normal Drench User defined 20 to 70 rpm. 13. Dispensing stop 1 Selection choice: – No The dispensing process takes place at the same time as the following programme steps. Dispensing stops at the end of wash time 1. – Yes Start drum rotation Auto load adjustment 0 mm to level 1 Water level 0 mm to level 1 Water volume 0 l to level 1 Laundry to suds ratio 1:0 to 1:20 kg/l Long dispensing phases are not stopped. The subsequent wash time 1 will not start until the dispensing procedure is complete. – X with dispensing type set to "No" 24 M.-Nr. 06 533 430