Download Electrolux EHG 65 Technical data

Transcript
Instructions for the Installer
Engineers technical data
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
OVERALL DIMENSIONS
Width:
580 mm.
Depth:
500 mm.
Electric:
230-240V 50Hz supply
CUT OUT DIMENSIONS
Width:
550 mm.
Depth:
470 mm.
TYPE
OF BURNER
TYPE
OF GAS
APPLIANCE GAS SUPPLY:
Natural gas 1.0 kPa - Universal LPG 2.75 kPa
NOZZLE
NOMINAL
MARKS
GAS
1/100 mm CONSUMPTION
MJ/h
NOMINAL
PRESSURE
kPa
NATURAL
GAS
Triple Crown (wok)
Semi-rapid (medium)
Auxiliary (small)
1.57
1.11
0.89
13.00
6.80
3.80
1.00
U-LPG
Triple Crown (wok)
Semi-rapid (medium)
Auxiliary (small)
0.97
0.71
0.55
13.00
6.30
3.80
2.75
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
35
Triple crown
42
Aeration adjustment none
Important safety requirements
Location
Choose a location free of draughts and open doors and
clear of combustible materials or other fire hazards such
as curtains, etc. The location should ensure convenience
of operation and service. Any adjacent wall surface
situated within 200mm from the edge of any hob burner
and above the height of the hob must be a suitable noncombustible material for a height of 150 mm for the entire
depth and width of the cooker.
FITTING THE GAS HOB
WITHOUT A COOKER HOOD ABOVE
700 mm
400 mm
55
50 m
mm
m
100
400 mm
mm
Any combustible material above the hotplate must be at
least 650 mm above the top of the hob and no
construction shall be within 450 mm above the top of the
burner.
50 m
m
FO 0812
FITTING THE GAS HOB
WITH A COOKER HOOD ABOVE
600 mm
A minimum distance of 100 mm. must be left between
the side edges of the hob and any adjacent cabinets or
walls.
650 mm
400 mm
55
50 m
mm
m
100
400 mm
mm
50 m
m
FO 0813
6