Command Reference Guide DDS Interface Configuration Command Set clock source [line | internal] Use the clock source command to configure the source timing used for the interface. The clock specified using the clock source command is also the system master clock. Use the no form of this command to return to the default value. Syntax Description internal Configures the unit to provide clocking using the internal oscillator. line Configures the unit to recover clocking from the DDS circuit. Default Values By default, the clock source is set to line. Applicable Platforms This command applies to the NetVanta 1000R, 3000, and 4000 Series units. Command History Release 1.1 Command was introduced. Functional Notes When operating on a DDS network, the clock source should be line. On a point-to-point private network, one unit must be line and the other internal. Usage Examples The following example configures the unit to recover clocking from the circuit: (config)#interface dds 1/1 (config-dds 1/1)#clock source line 61200510L1-35E Copyright © 2005 ADTRAN 580